Determination of resistance at zero and infinite frequencies in bioimpedance spectroscopy for assessment of body composition in babies

Natalia Pinheiro-Castro, Tamiris Ramos-Silva, Patricia Helen de Carvalho Rondó, Leigh C Ward iD

Physiological Measurement · 2024

DOI: 10.1088/1361-6579/ad3dc0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiological Measurement, 2024. Verfasst von Natalia Pinheiro-Castro und 3 weiteren Autor:innen. Beteiligte Einrichtung: Nutrition Department, School of Public Health, University of São Paulo, São Paulo, Brazil. Hauptthemen laut MEDLINE: Body Composition, Dielectric Spectroscopy, Electric Impedance. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação de Amparo à Pesquisa do Estado de São Paulo.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective . Bioimpedance spectroscopy (BIS) is a popular technique for the assessment of body composition in children and adults but has not found extensive use in babies and infants. This due primarily to technical difficulties of measurement in these groups. Although improvements in data modelling have, in part, mitigated this issue, the problem continues to yield unacceptably high rates of poor quality data. This study investigated an alternative data modelling procedure obviating issues associated with BIS measurements in babies and infants. Approach. BIS data are conventionally analysed according to the Cole model describing the impedance response of body tissues to an applied AC current. This approach is susceptible to errors due to capacitive leakage errors of measurement at high frequency. The alternative is to model BIS data based on the resistance–frequency spectrum rather than the reactance-resistance Cole model thereby avoiding capacitive error impacts upon reactance measurements. Main results. The resistance–frequency approach allowed analysis of 100% of data files obtained from BIS measurements in 72 babies compared to 87% successful analyses with the Cole model. Resistance–frequency modelling error (percentage standard error of the estimate) was half that of the Cole method. Estimated resistances at zero and infinite frequency were used to predict body composition. Resistance-based prediction of fat-free mass (FFM) exhibited a 30% improvement in the two-standard deviation limits of agreement with reference FFM measured by air displacement plethysmography when compared to Cole model-based predictions. Significance. This study has demonstrated improvement in the analysis of BIS data based on the resistance frequency response rather than conventional Cole modelling. This approach is recommended for use where BIS data are compromised by high frequency capacitive leakage errors such as those obtained in babies and infants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Body CompositionDielectric SpectroscopyElectric ImpedanceHumansInfantInfant, NewbornMaleFemale

Stichwörter der Autor:innen

babies and infantsbioimpedance spectroscopybody compositioncole modelresistance–frequency model

Autor:innen und Institutionen

  • Nutrition Department, School of Public Health, University of São Paulo, São Paulo, Brazil.
  • School of Chemistry and Molecular Biosciences, The University of Queensland, St. Lucia, Brisbane, Australia.

ORCID-Profile: Leigh C Ward

Förderung

  • Fundação de Amparo à Pesquisa do Estado de São Paulo

Zitieren

APA

Pinheiro-Castro, N., Ramos-Silva, T., de Carvalho Rondó, P. H., & Ward, L. C. (2024). Determination of resistance at zero and infinite frequencies in bioimpedance spectroscopy for assessment of body composition in babies. Physiological Measurement. https://doi.org/10.1088/1361-6579/ad3dc0

Vancouver

Pinheiro-Castro N, Ramos-Silva T, de Carvalho Rondó PH, Ward LC. Determination of resistance at zero and infinite frequencies in bioimpedance spectroscopy for assessment of body composition in babies. Physiological Measurement. 2024. doi:10.1088/1361-6579/ad3dc0

BibTeX
@article{PinheiroCastro2024,
  author = {Pinheiro-Castro, Natalia and Ramos-Silva, Tamiris and de Carvalho Rondó, Patricia Helen and Ward, Leigh C},
  title = {Determination of resistance at zero and infinite frequencies in bioimpedance spectroscopy for assessment of body composition in babies},
  journal = {Physiological Measurement},
  year = {2024},
  doi = {10.1088/1361-6579/ad3dc0}
}