Integration of Hollow Microneedle Arrays with Jellyfish-Shaped Electrochemical Sensor for the Detection of Biomarkers in Interstitial Fluid
Sensors · 2024
DOI: 10.3390/s24123729 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Fangfang Luo und 11 weiteren Autor:innen. Beteiligte Einrichtung: School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai 200093, China. Hauptthemen laut MEDLINE: Extracellular Fluid, Biomarkers, Biosensing Techniques, Electrochemical Techniques. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: High-end Foreign Experts.
Abstract (Originalsprache)
This study integrates hollow microneedle arrays (HMNA) with a novel jellyfish-shaped electrochemical sensor for the detection of key biomarkers, including uric acid (UA), glucose, and pH, in artificial interstitial fluid. The jellyfish-shaped sensor displayed linear responses in detecting UA and glucose via differential pulse voltammetry (DPV) and chronoamperometry, respectively. Notably, the open circuit potential (OCP) of the system showed a linear variation with pH changes, validating its pH-sensing capability. The sensor system demonstrates exceptional electrochemical responsiveness within the physiological concentration ranges of these biomarkers in simulated epidermis sensing applications. The detection linear ranges of UA, glucose, and pH were 0~0.8 mM, 0~7 mM, and 4.0~8.0, respectively. These findings highlight the potential of the HMNA-integrated jellyfish-shaped sensors in real-world epidermal applications for comprehensive disease diagnosis and health monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Health Science and Engineering, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai 200093, China.
- UFR Sciences, Université de Perpignan Via Domitia, 52 Avenue Paul Alduy, CEDEX, 66860 Perpignan, France.
ORCID-Profile: Zhanhong Li, Wen Sun, Zifeng Wang, Jean-Louis Marty
Förderung
- High-end Foreign Experts
Zitieren
APA
Luo, F., Li, Z., Shi, Y., Sun, W., Wang, Y., Sun, J., Fan, Z., Chang, Y., Wang, Z., Han, Y., Zhu, Z., & Marty, J. L. (2024). Integration of Hollow Microneedle Arrays with Jellyfish-Shaped Electrochemical Sensor for the Detection of Biomarkers in Interstitial Fluid. Sensors. https://doi.org/10.3390/s24123729
Vancouver
Luo F, Li Z, Shi Y, Sun W, Wang Y, Sun J, et al. Integration of Hollow Microneedle Arrays with Jellyfish-Shaped Electrochemical Sensor for the Detection of Biomarkers in Interstitial Fluid. Sensors. 2024. doi:10.3390/s24123729
BibTeX
@article{Luo2024,
author = {Luo, Fangfang and Li, Zhanhong and Shi, Yiping and Sun, Wen and Wang, Yuwei and Sun, Jianchao and Fan, Zheyuan and Chang, Yanyi and Wang, Zifeng and Han, Yutong and Zhu, Zhigang and Marty, Jean-Louis},
title = {Integration of Hollow Microneedle Arrays with Jellyfish-Shaped Electrochemical Sensor for the Detection of Biomarkers in Interstitial Fluid},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24123729}
}
EUVIMED