EUVIMEDEUVIMED entdecken
Crossref

An electrochromism-equipped enzymatic biofuel cell system combined with hollow microneedle array for self-powered glucose sensing in interstitial fluid

Nan Xiao, Haotian Li, Zheyuan Fan, Fangfang Luo, Dingxi Lu, Wen Sun, Zhanhong Li, Zifeng Wang, Yutong Han, Zhigang Zhu

Microchimica Acta · 2025-04 · 192 (4)

DOI: 10.1007/s00604-025-07096-y ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 12.03.2025. Verfasst von Nan Xiao und 9 weiteren Autor:innen. Beteiligte Einrichtung: School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 20093, China. Hauptthemen laut MEDLINE: Bioelectric Energy Sources, Glucose, Extracellular Fluid, Biosensing Techniques. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 43 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A disposable, self-powered enzymatic biofuel cell (BFC) sensor integrated with a hollow microneedle array (HMNA) for glucose monitoring in interstitial fluid (ISF) is reported. The HMNA enables painless and minimally invasive ISF extraction. The BFC uses dehydrogenase (GDH) in conjunction with NAD+, diaphorase (DI), and vitamin K3 (VK3) serving as electron transfer mediators as the anode catalyst and Prussian blue (PB) as the electrochromic cathode. Glucose oxidation at the anode generates electrons that cause PB to change the color at the cathode, allowing for visual glucose concentration determination. The open-circuit potential (OCP) of the sensor is 0.14 V, with a maximum power density of 0.07 µW·cm-2, at a glucose concentration of 14 mM. The sensor shows good performance in glucose sensing with a linear relationship between the R/B ratio and glucose concentrations ranging from 0 to 14 mM. This disposable device offers a promising approach for non-invasive and self-powered glucose sensing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bioelectric Energy SourcesGlucoseExtracellular FluidBiosensing TechniquesElectrochemical TechniquesNeedlesFerrocyanidesElectrodesGlucose 1-DehydrogenaseHumansEnzymes, Immobilized

Stichwörter der Autor:innen

Biofuel cellElectrochromicGlucoseMicroneedleSelf-powered sensorVisual color detection

Substanzen

GlucoseFerrocyanidesGlucose 1-DehydrogenaseEnzymes, Immobilizedferric ferrocyanide

Autor:innen und Institutionen

  • School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 20093, China.
  • School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 20093, China. zhli@usst.edu.cn.

Zitieren

APA

Xiao, N., Li, H., Fan, Z., Luo, F., Lu, D., Sun, W., Li, Z., Wang, Z., Han, Y., & Zhu, Z. (2025). An electrochromism-equipped enzymatic biofuel cell system combined with hollow microneedle array for self-powered glucose sensing in interstitial fluid. Microchimica Acta, 192(4). https://doi.org/10.1007/s00604-025-07096-y

Vancouver

Xiao N, Li H, Fan Z, Luo F, Lu D, Sun W, et al. An electrochromism-equipped enzymatic biofuel cell system combined with hollow microneedle array for self-powered glucose sensing in interstitial fluid. Microchimica Acta. 2025;192(4). doi:10.1007/s00604-025-07096-y

BibTeX
@article{Xiao2025,
  author = {Xiao, Nan and Li, Haotian and Fan, Zheyuan and Luo, Fangfang and Lu, Dingxi and Sun, Wen and Li, Zhanhong and Wang, Zifeng and Han, Yutong and Zhu, Zhigang},
  title = {An electrochromism-equipped enzymatic biofuel cell system combined with hollow microneedle array for self-powered glucose sensing in interstitial fluid},
  journal = {Microchimica Acta},
  year = {2025},
  volume = {192},
  number = {4},
  doi = {10.1007/s00604-025-07096-y}
}
Kostenlos starten →