EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Compound Acoustic Radiation Force Impulse Imaging of Bovine Eye by Using Phase-Inverted Ultrasound Transducer

Gil Su Kim, Hak Hyun Moon, Hee Su Lee, Jong Seob Jeong

Sensors · 2024

DOI: 10.3390/s24092700 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Gil Su Kim und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Dongguk University, Seoul 04620, Republic of Korea. Hauptthemen laut MEDLINE: Transducers, Eye, Signal-To-Noise Ratio, Elasticity Imaging Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korean Government.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In general, it is difficult to visualize internal ocular structure and detect a lesion such as a cataract or glaucoma using the current ultrasound brightness-mode (B-mode) imaging. This is because the internal structure of the eye is rich in moisture, resulting in a lack of contrast between tissues in the B-mode image, and the penetration depth is low due to the attenuation of the ultrasound wave. In this study, the entire internal ocular structure of a bovine eye was visualized in an ex vivo environment using the compound acoustic radiation force impulse (CARFI) imaging scheme based on the phase-inverted ultrasound transducer (PIUT). In the proposed method, the aperture of the PIUT is divided into four sections, and the PIUT is driven by the out-of-phase input signal capable of generating split-focusing at the same time. Subsequently, the compound imaging technique was employed to increase signal-to-noise ratio (SNR) and to reduce displacement error. The experimental results demonstrated that the proposed technique could provide an acoustic radiation force impulse (ARFI) image of the bovine eye with a broader depth-of-field (DOF) and about 80% increased SNR compared to the conventional ARFI image obtained using the in-phase input signal. Therefore, the proposed technique can be one of the useful techniques capable of providing the image of the entire ocular structure to diagnose various eye diseases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TransducersEyeSignal-To-Noise RatioElasticity Imaging TechniquesAnimalsCattleUltrasonography

Stichwörter der Autor:innen

compound acoustic radiation force impulse imagingdepth-of-fieldinternal ocular structurephase-inverted ultrasound transducer

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Dongguk University, Seoul 04620, Republic of Korea.

Förderung

  • Korean Government

Zitieren

APA

Kim, G. S., Moon, H. H., Lee, H. S., & Jeong, J. S. (2024). Compound Acoustic Radiation Force Impulse Imaging of Bovine Eye by Using Phase-Inverted Ultrasound Transducer. Sensors. https://doi.org/10.3390/s24092700

Vancouver

Kim GS, Moon HH, Lee HS, Jeong JS. Compound Acoustic Radiation Force Impulse Imaging of Bovine Eye by Using Phase-Inverted Ultrasound Transducer. Sensors. 2024. doi:10.3390/s24092700

BibTeX
@article{Kim2024,
  author = {Kim, Gil Su and Moon, Hak Hyun and Lee, Hee Su and Jeong, Jong Seob},
  title = {Compound Acoustic Radiation Force Impulse Imaging of Bovine Eye by Using Phase-Inverted Ultrasound Transducer},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24092700}
}
Kostenlos starten →