EUVIMEDEUVIMED entdecken
Crossref

Element Position Calibration for Matrix Array Transducers with Multiple Disjoint Piezoelectric Panels

Jacob R McCall, Arthur Chavignon, Olivier Couture, Paul A Dayton, Gianmarco F Pinton iD

Ultrasonic Imaging · 2024

DOI: 10.1177/01617346241227900 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ultrasonic Imaging, 2024. Verfasst von Jacob R McCall und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, North Carolina State University, Raleigh, NC, USA. Hauptthemen laut MEDLINE: Transducers, Ultrasonography, Signal-To-Noise Ratio, Equipment Design. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: NINDS NIH HHS, NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Two-dimensional ultrasound transducers enable the acquisition of fully volumetric data that have been demonstrated to provide greater diagnostic information in the clinical setting and are a critical tool for emerging ultrasound methods, such as super-resolution and functional imaging. This technology, however, is not without its limitations. Due to increased fabrication complexity, some matrix probes with disjoint piezoelectric panels may require initial calibration. In this manuscript, two methods for calibrating the element positions of the Vermon 1024-channel 8 MHz matrix transducer are detailed. This calibration is a necessary step for acquiring high resolution B-mode images while minimizing transducer-based image degradation. This calibration is also necessary for eliminating vessel-doubling artifacts in super-resolution images and increasing the overall signal-to-noise ratio (SNR) of the image. Here, we show that the shape of the point spread function (PSF) can be significantly improved and PSF-doubling artifacts can be reduced by up to 10 dB via this simple calibration procedure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TransducersUltrasonographySignal-To-Noise RatioEquipment DesignArtifactsCalibrationPhantoms, Imaging

Stichwörter der Autor:innen

3-D ultrasoundULMcalibrationtransducer

Autor:innen und Institutionen

  • Department of Electrical Engineering, North Carolina State University, Raleigh, NC, USA.
  • Joint-Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC, USA.
  • Department Laboratoire d'Imagerie, Sorbonne Université, CNRS INSERM, Paris, France.

ORCID-Profile: Gianmarco F Pinton

Förderung

  • NINDS NIH HHS
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

McCall, J. R., Chavignon, A., Couture, O., Dayton, P. A., & Pinton, G. F. (2024). Element Position Calibration for Matrix Array Transducers with Multiple Disjoint Piezoelectric Panels. Ultrasonic Imaging. https://doi.org/10.1177/01617346241227900

Vancouver

McCall JR, Chavignon A, Couture O, Dayton PA, Pinton GF. Element Position Calibration for Matrix Array Transducers with Multiple Disjoint Piezoelectric Panels. Ultrasonic Imaging. 2024. doi:10.1177/01617346241227900

BibTeX
@article{McCall2024,
  author = {McCall, Jacob R and Chavignon, Arthur and Couture, Olivier and Dayton, Paul A and Pinton, Gianmarco F},
  title = {Element Position Calibration for Matrix Array Transducers with Multiple Disjoint Piezoelectric Panels},
  journal = {Ultrasonic Imaging},
  year = {2024},
  doi = {10.1177/01617346241227900}
}
Kostenlos starten →