EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Torque–Cadence Profile and Maximal Dynamic Force in Cyclists: A Novel Approach

Víctor Rodríguez-Rielves, David Barranco-Gil iD, Ángel Buendía-Romero iD, Alejandro Hernández-Belmonte iD, Enrique Higueras-Liébana, Jon Iriberri, Iván R Sánchez-Redondo iD, José Ramón Lillo-Beviá iD, Alejandro Martínez-Cava, Raúl de Pablos, Pedro L Valenzuela iD, Jesús G Pallarés iD und 1 weitere

Sensors · 2024

DOI: 10.3390/s24061997 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Víctor Rodríguez-Rielves und 12 weiteren Autor:innen. Beteiligte Einrichtung: Human Performance and Sports Science Laboratory, Faculty of Sport Sciences, University of Murcia, 30720 Murcia, Spain. Hauptthemen laut MEDLINE: Bicycling, Ergometry. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Instituto de Salud Carlos III, Spanish Ministry of Economy and Competitiveness and Fondos FEDER, Spanish Ministry of Education, Culture and Sports.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We aimed to determine the feasibility, test–retest reliability and long-term stability of a novel method for assessing the force (torque)-velocity (cadence) profile and maximal dynamic force (MDF) during leg-pedaling using a friction-loaded isoinertial cycle ergometer and a high-precision power-meter device. Fifty-two trained male cyclists completed a progressive loading test up to the one-repetition maximum (1RM) on a cycle ergometer. The MDF was defined as the force attained at the cycle performed with the 1RM-load. To examine the test–retest reliability and long-term stability of torque–cadence values, the progressive test was repeated after 72 h and also after 10 weeks of aerobic and strength training. The participants’ MDF averaged 13.4 ± 1.3 N·kg−1, which was attained with an average pedal cadence of 21 ± 3 rpm. Participants’ highest power output value was attained with a cadence of 110 ± 16 rpm (52 ± 5% MDF). The relationship between the MDF and cadence proved to be very strong (R2 = 0.978) and independent of the cyclists’ MDF (p = 0.66). Cadence values derived from this relationship revealed a very high test–retest repeatability (mean SEM = 4 rpm, 3.3%) and long-term stability (SEM = 3 rpm, 2.3%); despite increases in the MDF following the 10-week period. Our findings support the validity, reliability and long-term stability of this method for the assessment of the torque–cadence profile and MDF in cyclists.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BicyclingErgometryHumansMaleTorqueReproducibility of ResultsFootExercise Test

Stichwörter der Autor:innen

assessmentcyclingforcelaboratorytesting

Autor:innen und Institutionen

  • Human Performance and Sports Science Laboratory, Faculty of Sport Sciences, University of Murcia, 30720 Murcia, Spain.
  • Faculty of Sport Sciences, European University of Madrid, 28670 Madrid, Spain.
  • GENUD Toledo Research Group, Faculty of Sports Sciences, University of Castilla-La Mancha, 45071 Toledo, Spain.
  • Jumbo Visma Professional Cycling Team, 5215 MV Den Bosch, The Netherlands.
  • Physical Activity and Health Research Group (PaHerg), Research Institute of Hospital 12 de Octubre (Imas12), 28041 Madrid, Spain.
  • Department of Systems Biology, University of Alcalá, 28871 Madrid, Spain.

ORCID-Profile: David Barranco-Gil, Ángel Buendía-Romero, Alejandro Hernández-Belmonte, Iván R Sánchez-Redondo, José Ramón Lillo-Beviá, Pedro L Valenzuela, Jesús G Pallarés, Lidia B Alejo

Förderung

  • Instituto de Salud Carlos III
  • Spanish Ministry of Economy and Competitiveness and Fondos FEDER
  • Spanish Ministry of Education, Culture and Sports

Zitieren

APA

Rodríguez-Rielves, V., Barranco-Gil, D., Buendía-Romero, Á., Hernández-Belmonte, A., Higueras-Liébana, E., Iriberri, J., Sánchez-Redondo, I. R., Lillo-Beviá, J. R., Martínez-Cava, A., de Pablos, R., Valenzuela, P. L., Pallarés, J. G., & Alejo, L. B. (2024). Torque–Cadence Profile and Maximal Dynamic Force in Cyclists: A Novel Approach. Sensors. https://doi.org/10.3390/s24061997

Vancouver

Rodríguez-Rielves V, Barranco-Gil D, Buendía-Romero Á, Hernández-Belmonte A, Higueras-Liébana E, Iriberri J, et al. Torque–Cadence Profile and Maximal Dynamic Force in Cyclists: A Novel Approach. Sensors. 2024. doi:10.3390/s24061997

BibTeX
@article{RodrguezRielves2024,
  author = {Rodríguez-Rielves, Víctor and Barranco-Gil, David and Buendía-Romero, Ángel and Hernández-Belmonte, Alejandro and Higueras-Liébana, Enrique and Iriberri, Jon and Sánchez-Redondo, Iván R and Lillo-Beviá, José Ramón and Martínez-Cava, Alejandro and de Pablos, Raúl and Valenzuela, Pedro L and Pallarés, Jesús G and Alejo, Lidia B},
  title = {Torque–Cadence Profile and Maximal Dynamic Force in Cyclists: A Novel Approach},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24061997}
}
Kostenlos starten →