EUVIMEDEUVIMED entdecken
VergleichsstudieValidierungsstudieOpen Access · CC BY 4.0

Determining V̇O2max in competitive swimmers: Comparing the validity and reliability of cycling, arm cranking, ergometer swimming, and tethered swimming

Michel de Haan, Stephan van der Zwaard, Sander Schreven, Peter J Beek, Richard T Jaspers

Journal of Science and Medicine in Sport · 2024-07 · 27 (7) · 499-506

DOI: 10.1016/j.jsams.2024.03.015 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Science and Medicine in Sport, 2024-07. Verfasst von Michel de Haan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Human Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Netherlands. Electronic address: https://twitter.co…. Hauptthemen laut MEDLINE: Swimming, Exercise Test, Bicycling, Oxygen Consumption. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ZonMw.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: This study aims to identify the optimal method for determining V̇O2max in competitive swimmers in terms of validity and test-retest reliability. DESIGN: Controlled experiment. METHODS: Twenty competitive swimmers performed four maximal incremental exercise tests: cycling, arm cranking, ergometer swimming, and tethered swimming. Gas analysis was conducted to estimate V̇O2max. Validity was assessed in terms of the amount of variance of the performance on a 1500-m time trial explained by the estimated V̇O2max . Test-retest reliability was evaluated using the intraclass correlation coefficient (ICC). RESULTS: V̇O2max obtained from tethered swimming, ergometer swimming, and cycling explained a similar amount of variance of the 1500-m performance (R2 = 0.64, 0.64 and 0.65, respectively). However, ergometer swimming yielded significantly lower V̇O2max estimates (40.54 ± 6.55 ml/kg/min) than tethered swimming (54.40 ± 6.21 ml/kg/min) and cycling (54.39 ± 5.63 ml/kg/min). Arm cranking resulted in both a lower explained variance (R2 = 0.41) and a significantly lower V̇O2max (43.14 ± 7.81 ml/kg/min). Tethered swimming showed good reliability (ICC = 0.81). CONCLUSIONS: Bicycle and tethered swimming tests demonstrated high validity with comparable V̇O2max estimates, explaining a large proportion of differences in endurance performance. Choosing between these two methods involves a trade-off between a higher practical applicability and reliability of the bicycle test and the more sport-specific nature of the tethered swimming test.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SwimmingExercise TestBicyclingOxygen ConsumptionErgometryHumansReproducibility of ResultsMaleYoung AdultAdolescentFemaleAthletic PerformanceArm

Stichwörter der Autor:innen

AthletesEndurance capacityExercise testingReproducibilityTest–retest reliabilityV̇O(2)peak

Autor:innen und Institutionen

  • Department of Human Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Netherlands. Electronic address: https://twitter.com/Md_Haan.
  • Department of Human Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Netherlands; Department of Cardiology, Amsterdam University Medical Center, University of Amsterdam, Netherlands.
  • InnosportLab De Tongelreep, Netherlands.
  • Department of Human Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Netherlands.
  • Department of Human Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Netherlands. Electronic address: r.t.jaspers@vu.nl.

Förderung

  • ZonMw

Zitieren

APA

de Haan, M., van der Zwaard, S., Schreven, S., Beek, P. J., & Jaspers, R. T. (2024). Determining V̇O2max in competitive swimmers: Comparing the validity and reliability of cycling, arm cranking, ergometer swimming, and tethered swimming. Journal of Science and Medicine in Sport, 27(7), 499-506. https://doi.org/10.1016/j.jsams.2024.03.015

Vancouver

de Haan M, van der Zwaard S, Schreven S, Beek PJ, Jaspers RT. Determining V̇O2max in competitive swimmers: Comparing the validity and reliability of cycling, arm cranking, ergometer swimming, and tethered swimming. Journal of Science and Medicine in Sport. 2024;27(7):499-506. doi:10.1016/j.jsams.2024.03.015

BibTeX
@article{deHaan2024,
  author = {de Haan, Michel and van der Zwaard, Stephan and Schreven, Sander and Beek, Peter J and Jaspers, Richard T},
  title = {Determining V̇O2max in competitive swimmers: Comparing the validity and reliability of cycling, arm cranking, ergometer swimming, and tethered swimming},
  journal = {Journal of Science and Medicine in Sport},
  year = {2024},
  volume = {27},
  number = {7},
  pages = {499--506},
  doi = {10.1016/j.jsams.2024.03.015}
}