Concurrent Validity and Reliability of Two Portable Powermeters (Power2Max vs. PowerTap) to Measure Different Types of Efforts in Cycling
Sensors · 2023
DOI: 10.3390/s23187745 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Javier Iglesias-Pino und 3 weiteren Autor:innen. Beteiligte Einrichtung: Human Movement and Sports Performance Analysis (AMRED), Faculty of Physical Activity and Sports Sciences, Universidad de León, 24071 León, Spain. Hauptthemen laut MEDLINE: Bicycling. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The purpose was to assess the concurrent validity and reliability of two portable powermeters (PowerTap vs. Power2Max) in different types of cycling efforts. Ten cyclists performed two submaximal, one incremental maximal and two supramaximal sprint tests on an ergometer, while pedaling power and cadence were registered by both powermeters and a cadence sensor (GarminGSC10). During the submaximal and incremental maximal tests, significant correlations were found for power and cadence data (r = 0.992–0.997 and 0.996–0.998, respectively, p < 0.001), with a slight power underestimation by PowerTap (0.7–1.8%, p < 0.01) and a high reliability of both powermeters (p < 0.001) for measurement of power (ICC = 0.926 and 0.936, respectively) and cadence (ICC = 0.969 and 0.970, respectively). However, during the supramaximal sprint test, their agreement to measure power and cadence was weak (r = 0.850 and −0.253, p < 0.05) due to the low reliability of the cadence measurements (ICC between 0.496 and 0.736, and 0.574 and 0.664, respectively; p < 0.05) in contrast to the high reliability of the cadence sensor (ICC = 0.987–0.994). In conclusion, both powermeters are valid and reliable for measuring power and cadence during continuous cycling efforts (~100–450 W), but questionable during sprint efforts (>500 W), where they are affected by the gear ratio used (PowerTap) and by their low accuracy in cadence recording (PowerTap and Power2Max).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Human Movement and Sports Performance Analysis (AMRED), Faculty of Physical Activity and Sports Sciences, Universidad de León, 24071 León, Spain.
- Grupo de Investigación en Ciencias del Deporte (INCIDE), Departamento de Educación Física y Deportiva, Universidade da Coruña, 15179 A Coruña, Spain.
ORCID-Profile: Alba Herrero-Molleda, Miguel Ángel Saavedra-García, Juan García-López
Zitieren
APA
Iglesias-Pino, J., Herrero-Molleda, A., Saavedra-García, M. Á., & García-López, J. (2023). Concurrent Validity and Reliability of Two Portable Powermeters (Power2Max vs. PowerTap) to Measure Different Types of Efforts in Cycling. Sensors. https://doi.org/10.3390/s23187745
Vancouver
Iglesias-Pino J, Herrero-Molleda A, Saavedra-García MÁ, García-López J. Concurrent Validity and Reliability of Two Portable Powermeters (Power2Max vs. PowerTap) to Measure Different Types of Efforts in Cycling. Sensors. 2023. doi:10.3390/s23187745