EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Analytical Analysis of Factors Affecting the Accuracy of a Dual-Heat Flux Core Body Temperature Sensor

Jakub Żmigrodzki iD, Szymon Cygan iD, Jan Łusakowski, Patryk Lamprecht iD

Sensors · 15.03.2024 · 24 (6) · 1887

DOI: 10.3390/s24061887 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 15.03.2024. Verfasst von Jakub Żmigrodzki und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Metrology and Biomedical Engineering, Faculty of Mechatronics, Warsaw University of Technology, 02-525 Warsaw, Poland. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Non-invasive core body temperature (CBT) measurements using temperature and heat-flux have become popular in health, sports, work safety, and general well-being applications. This research aimed to evaluate two commonly used sensor designs: those that combine heat flux and temperature sensors, and those with four temperature sensors. We used analytical methods, particularly uncertainty analysis calculus and Monte Carlo simulations, to analyse measurement accuracy, which depends on the accuracy of the temperature and flux sensors, mechanical construction parameters (such as heat transfer coefficient), ambient air temperature, and CBT values. The results show the relationship between the accuracy of each measurement method variant and various sensor parameters, indicating their suitability for different scenarios. All measurement variants showed unstable behaviour around the point where ambient temperature equals CBT. The ratio of the heat transfer coefficients of the dual-heat flux (DHF) sensor’s channels impacts the CBT estimation uncertainty. An analysis of the individual components of uncertainty in CBT estimates reveals that the accuracy of temperature sensors significantly impacts the overall uncertainty of the CBT measurement. We also calculated the theoretical limits of measurement uncertainty, which varied depending on the method variant and could be as low as 0.05 °C.

Schlagwörter

Stichwörter der Autor:innen

Monte Carlocore body temperaturedual heat-flux sensormeasurement accuracy

Autor:innen und Institutionen

  • Institute of Metrology and Biomedical Engineering, Faculty of Mechatronics, Warsaw University of Technology, 02-525 Warsaw, Poland.
  • Healthwear Sp. z o.o., 31-539 Cracow, Poland.

ORCID-Profile: Jakub Żmigrodzki, Szymon Cygan, Patryk Lamprecht

Zitieren

APA

Żmigrodzki, J., Cygan, S., Łusakowski, J., & Lamprecht, P. (2024). Analytical Analysis of Factors Affecting the Accuracy of a Dual-Heat Flux Core Body Temperature Sensor. Sensors, 24(6), 1887. https://doi.org/10.3390/s24061887

Vancouver

Żmigrodzki J, Cygan S, Łusakowski J, Lamprecht P. Analytical Analysis of Factors Affecting the Accuracy of a Dual-Heat Flux Core Body Temperature Sensor. Sensors. 2024;24(6):1887. doi:10.3390/s24061887

BibTeX
@article{migrodzki2024,
  author = {Żmigrodzki, Jakub and Cygan, Szymon and Łusakowski, Jan and Lamprecht, Patryk},
  title = {Analytical Analysis of Factors Affecting the Accuracy of a Dual-Heat Flux Core Body Temperature Sensor},
  journal = {Sensors},
  year = {2024},
  volume = {24},
  number = {6},
  pages = {1887},
  doi = {10.3390/s24061887}
}
Kostenlos starten →