EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design, Fabrication and Evaluation of a Stretchable High-Density Electromyography Array

Rejin John Varghese iD, Matteo Pizzi iD, Aritra Kundu iD, Agnese Grison iD, Etienne Burdet iD, Dario Farina iD

Sensors · 2024

DOI: 10.3390/s24061810 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Rejin John Varghese und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, Faculty of Engineering, Imperial College London, London W12 0BZ, UK. Hauptthemen laut MEDLINE: Artifacts. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council, Non-Invasive Single Neuron Electrical Monitoring (NISNEM), UK Research and Innovation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The adoption of high-density electrode systems for human–machine interfaces in real-life applications has been impeded by practical and technical challenges, including noise interference, motion artefacts and the lack of compact electrode interfaces. To overcome some of these challenges, we introduce a wearable and stretchable electromyography (EMG) array, and present its design, fabrication methodology, characterisation, and comprehensive evaluation. Our proposed solution comprises dry-electrodes on flexible printed circuit board (PCB) substrates, eliminating the need for time-consuming skin preparation. The proposed fabrication method allows the manufacturing of stretchable sleeves, with consistent and standardised coverage across subjects. We thoroughly tested our developed prototype, evaluating its potential for application in both research and real-world environments. The results of our study showed that the developed stretchable array matches or outperforms traditional EMG grids and holds promise in furthering the real-world translation of high-density EMG for human–machine interfaces.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsHumansElectromyographyElectrodesMotion

Stichwörter der Autor:innen

HD-EMGhuman–machine interfacingsoft robotics and sensingsurface electromyographywearable sensors

Autor:innen und Institutionen

  • Department of Bioengineering, Faculty of Engineering, Imperial College London, London W12 0BZ, UK.

ORCID-Profile: Rejin John Varghese, Matteo Pizzi, Aritra Kundu, Agnese Grison, Etienne Burdet, Dario Farina

Förderung

  • Engineering and Physical Sciences Research Council
  • Non-Invasive Single Neuron Electrical Monitoring (NISNEM)
  • UK Research and Innovation
  • Huawei Technologies Research & Development (UK) Limited

Zitieren

APA

Varghese, R. J., Pizzi, M., Kundu, A., Grison, A., Burdet, E., & Farina, D. (2024). Design, Fabrication and Evaluation of a Stretchable High-Density Electromyography Array. Sensors. https://doi.org/10.3390/s24061810

Vancouver

Varghese RJ, Pizzi M, Kundu A, Grison A, Burdet E, Farina D. Design, Fabrication and Evaluation of a Stretchable High-Density Electromyography Array. Sensors. 2024. doi:10.3390/s24061810

BibTeX
@article{Varghese2024,
  author = {Varghese, Rejin John and Pizzi, Matteo and Kundu, Aritra and Grison, Agnese and Burdet, Etienne and Farina, Dario},
  title = {Design, Fabrication and Evaluation of a Stretchable High-Density Electromyography Array},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24061810}
}
Kostenlos starten →