EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Motion Artifacts in Dynamic EEG Recordings: Experimental Observations, Electrical Modelling, and Design Considerations

Alessandra Giangrande iD, Alberto Botter iD, Harri Piitulainen iD, Giacinto Luigi Cerone iD

Sensors · 2024

DOI: 10.3390/s24196363 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Alessandra Giangrande und 3 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Neuromuscular System and Rehabilitation Engineering, Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Tur…. Hauptthemen laut MEDLINE: Electroencephalography, Artifacts, Electrodes. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Academy of Finland, JYU Visiting Fellow Programme Grant 2023, Faculty of Sports and Health Sciences of the University of Jyväskylä.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Despite the progress in the development of innovative EEG acquisition systems, their use in dynamic applications is still limited by motion artifacts compromising the interpretation of the collected signals. Therefore, extensive research on the genesis of motion artifacts in EEG recordings is still needed to optimize existing technologies, shedding light on possible solutions to overcome the current limitations. We identified three potential sources of motion artifacts occurring at three different levels of a traditional biopotential acquisition chain: the skin-electrode interface, the connecting cables between the detection and the acquisition systems, and the electrode-amplifier system. The identified sources of motion artifacts were modelled starting from experimental observations carried out on EEG signals. Consequently, we designed customized EEG electrode systems aiming at experimentally disentangling the possible causes of motion artifacts. Both analytical and experimental observations indicated two main residual sites responsible for motion artifacts: the connecting cables between the electrodes and the amplifier and the sudden changes in electrode-skin impedance due to electrode movements. We concluded that further advancements in EEG technology should focus on the transduction stage of the biopotentials amplification chain, such as the electrode technology and its interfacing with the acquisition system.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectroencephalographyArtifactsElectrodesHumansSignal Processing, Computer-AssistedMotionAmplifiers, ElectronicElectric ImpedanceEquipment Design

Stichwörter der Autor:innen

EEG cap designEEG electrodesbiomedical instrumentationelectrode-amplifier system modellingelectroencephalographymotion artifactsthe brain

Autor:innen und Institutionen

  • Laboratory of Neuromuscular System and Rehabilitation Engineering, Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Turin, Italy.
  • Faculty of Sport and Health Sciences, University of Jyväskylä, 40014 Jyväskylä, Finland.

ORCID-Profile: Alessandra Giangrande, Alberto Botter, Harri Piitulainen, Giacinto Luigi Cerone

Förderung

  • Academy of Finland
  • JYU Visiting Fellow Programme Grant 2023
  • Faculty of Sports and Health Sciences of the University of Jyväskylä
  • Politecnico di Torino
  • JYU Visiting Fellow Programme

Zitieren

APA

Giangrande, A., Botter, A., Piitulainen, H., & Cerone, G. L. (2024). Motion Artifacts in Dynamic EEG Recordings: Experimental Observations, Electrical Modelling, and Design Considerations. Sensors. https://doi.org/10.3390/s24196363

Vancouver

Giangrande A, Botter A, Piitulainen H, Cerone GL. Motion Artifacts in Dynamic EEG Recordings: Experimental Observations, Electrical Modelling, and Design Considerations. Sensors. 2024. doi:10.3390/s24196363

BibTeX
@article{Giangrande2024,
  author = {Giangrande, Alessandra and Botter, Alberto and Piitulainen, Harri and Cerone, Giacinto Luigi},
  title = {Motion Artifacts in Dynamic EEG Recordings: Experimental Observations, Electrical Modelling, and Design Considerations},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24196363}
}
Kostenlos starten →