Wearable EMG Measurement Device Using Polyurethane Foam for Motion Artifact Suppression
Sensors · 08.05.2024 · 24 (10) · 2985
DOI: 10.3390/s24102985 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 08.05.2024. Verfasst von Takuma Takagi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Precision Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo 113-8654, Japan. Hauptthemen laut MEDLINE: Polyurethanes, Electromyography, Wearable Electronic Devices, Artifacts. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: New Energy and Industrial Technology Development Organization.
Abstract (Originalsprache)
We propose the use of a specially designed polyurethane foam with a plateau region in its mechanical characteristics—where stress remains nearly constant during deformation—between the electromyography (EMG) electrode and clothing to suppress motion artifacts in EMG measurement. Wearable EMG devices are receiving attention for monitoring muscle weakening due to aging. However, daily EMG measurement has been challenging due to motion artifacts caused by changes in the contact pressure between the bioelectrode and the skin. Therefore, this study aims to measure EMG signals in daily movement environments by controlling the contact pressure using polyurethane foam between the bioelectrode on the clothing and the skin. Through mechanical calculations and finite element method simulations of the polyurethane foam’s effect, we clarified that the characteristics of the polyurethane foam significantly influence contact pressure control and that the contact pressure is adjustable through the polyurethane foam thickness. The optimization of the design successfully controlled the contact pressure between the bioelectrode and skin from 1.0 kPa to 2.0 kPa, effectively suppressing the motion artifact in EMG measurement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Precision Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo 113-8654, Japan.
ORCID-Profile: Seiichi Takamatsu
Förderung
- New Energy and Industrial Technology Development Organization
Zitieren
APA
Takagi, T., Tomita, N., Sato, S., Yamamoto, M., Takamatsu, S., & Itoh, T. (2024). Wearable EMG Measurement Device Using Polyurethane Foam for Motion Artifact Suppression. Sensors, 24(10), 2985. https://doi.org/10.3390/s24102985
Vancouver
Takagi T, Tomita N, Sato S, Yamamoto M, Takamatsu S, Itoh T. Wearable EMG Measurement Device Using Polyurethane Foam for Motion Artifact Suppression. Sensors. 2024;24(10):2985. doi:10.3390/s24102985
BibTeX
@article{Takagi2024,
author = {Takagi, Takuma and Tomita, Naoto and Sato, Suguru and Yamamoto, Michitaka and Takamatsu, Seiichi and Itoh, Toshihiro},
title = {Wearable EMG Measurement Device Using Polyurethane Foam for Motion Artifact Suppression},
journal = {Sensors},
year = {2024},
volume = {24},
number = {10},
pages = {2985},
doi = {10.3390/s24102985}
}
EUVIMED