Bridgman-Grown (Cd,Mn)Te and (Cd,Mn)(Te,Se): A Comparison of Suitability for X and Gamma Detectors
Sensors · 06.01.2024 · 24 (2) · 345
DOI: 10.3390/s24020345 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 06.01.2024. Verfasst von Aneta Masłowska und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Physics, Polish Academy of Sciences, Aleja Lotników 32/46, 02-668 Warsaw, Poland. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 83 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Centre for Research and Development, Foundation for Polish Science, Polish National Centre for Research and Development.
Abstract (Originalsprache)
This study explores the suitability of (Cd,Mn)Te and (Cd,Mn)(Te,Se) as room-temperature X-ray and gamma-ray detector materials, grown using the Bridgman method. The investigation compares their crystal structure, mechanical and optical properties, and radiation detection capabilities. Both crystals can yield large-area single crystal samples measuring approximately 30 × 30 mm2. In low-temperature photoluminescence analysis, both materials showed defect states, and annealing in cadmium vapors effectively eliminated donor–acceptor pair luminescence in (Cd,Mn)Te but not in (Cd,Mn)(Te,Se). Moreover, harder (Cd,Mn)(Te,Se) exhibited a higher etch pit density compared to softer (Cd,Mn)Te. X-ray diffraction examination revealed uniform lattice constant distribution in both compounds, with variations at a part per million level. (Cd,Mn)Te crystals demonstrated excellent single crystal properties with narrower omega scan widths, while (Cd,Mn)(Te,Se) exhibited a high contribution of block-like structures with significantly larger misorientation angles. Spectroscopic evaluations revealed better performance of a pixelated (Cd,Mn)Te detector, in comparison to (Cd,Mn)(Te,Se), achieving a mean full width at half maximum of 14% for the 122 keV gamma peak of Co-57. The reduced performance of the (Cd,Mn)(Te,Se) detector may be attributed to deep trap-related luminescence or block-like structures with larger misorientation angles. In conclusion, Bridgman-grown (Cd,Mn)Te emerges as a more promising material for X-ray and gamma-ray detectors when compared to (Cd,Mn)(Te,Se).
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Physics, Polish Academy of Sciences, Aleja Lotników 32/46, 02-668 Warsaw, Poland.
- International Research Centre MagTop, Institute of Physics, Polish Academy of Sciences, Aleja Lotników 32/46, 02-668 Warsaw, Poland.
- Faculty of Materials Science and Engineering, Warsaw University of Technology, Wołoska 141, 02-507 Warsaw, Poland.
- Puremat Technologies Sp. z o.o., Aleja Lotników 32/46, 02-668 Warsaw, Poland.
ORCID-Profile: Aneta Masłowska, Dominika M Kochanowska, Adrian Sulich, Jaroslaw Z Domagala, Michał Szot, Andrzej Mycielski
Förderung
- National Centre for Research and Development
- Foundation for Polish Science
- Polish National Centre for Research and Development
Zitieren
APA
Masłowska, A., Kochanowska, D. M., Sulich, A., Domagala, J. Z., Dopierała, M., Kochański, M., Szot, M., Chromiński, W., & Mycielski, A. (2024). Bridgman-Grown (Cd,Mn)Te and (Cd,Mn)(Te,Se): A Comparison of Suitability for X and Gamma Detectors. Sensors, 24(2), 345. https://doi.org/10.3390/s24020345
Vancouver
Masłowska A, Kochanowska DM, Sulich A, Domagala JZ, Dopierała M, Kochański M, et al. Bridgman-Grown (Cd,Mn)Te and (Cd,Mn)(Te,Se): A Comparison of Suitability for X and Gamma Detectors. Sensors. 2024;24(2):345. doi:10.3390/s24020345
BibTeX
@article{Masowska2024,
author = {Masłowska, Aneta and Kochanowska, Dominika M and Sulich, Adrian and Domagala, Jaroslaw Z and Dopierała, Marcin and Kochański, Michał and Szot, Michał and Chromiński, Witold and Mycielski, Andrzej},
title = {Bridgman-Grown (Cd,Mn)Te and (Cd,Mn)(Te,Se): A Comparison of Suitability for X and Gamma Detectors},
journal = {Sensors},
year = {2024},
volume = {24},
number = {2},
pages = {345},
doi = {10.3390/s24020345}
}
EUVIMED