Kurz gefasst

Übersichtsarbeit in der Zeitschrift Sensors, online erschienen am 13.03.2025. Verfasst von Anthony R Whittemore und 1 weiteren Autor:innen. Beteiligte Einrichtung: Walker Department of Mechanical Engineering, The University of Texas at Austin, Austin, TX 78712, USA. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 157 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This review explores the applications of room temperature semiconductor detectors, with a focus on Cd(Zn)Te based detection systems, in non-destructive testing and evaluation (NDT&E). Cd(Zn)Te detectors, which operate efficiently at ambient temperatures, eliminate the need for cryogenic cooling systems and offer high energy and spatial resolution, making them ideal for a wide range of NDT&E applications. Key performance parameters such as energy resolution, spatial resolution, time resolution, detector efficiency, and form factor are discussed. The paper highlights the utilization of Cd(Zn)Te detectors in various imaging and spectroscopic applications, including nuclear threat detection and non-proliferation, archaeological NDT, and Unmanned Aerial Vehicle radiological surveying. Cd(Zn)Te detectors hold significant promise in NDT&E due to their high-resolution imaging, superior spectroscopic capabilities, versatility, and portability.

Schlagwörter

Stichwörter der Autor:innen

NDTX-ray and gamma-ray detectorscompound semiconductor radiation detectorshigh-Z semiconductor radiation detectorsnon-destructive testingsemiconductor radiation detectors

Autor:innen und Institutionen

  • Walker Department of Mechanical Engineering, The University of Texas at Austin, Austin, TX 78712, USA.

ORCID-Profile: Anthony R Whittemore, Elena Maria Zannoni

Zitieren

APA

Whittemore, A. R., & Zannoni, E. M. (2025). Applications of Cd(Zn)Te Radiation Detectors in Non-Destructive Testing and Evaluation. Sensors, 25(6), 1776. https://doi.org/10.3390/s25061776

Vancouver

Whittemore AR, Zannoni EM. Applications of Cd(Zn)Te Radiation Detectors in Non-Destructive Testing and Evaluation. Sensors. 2025;25(6):1776. doi:10.3390/s25061776

BibTeX
@article{Whittemore2025,
  author = {Whittemore, Anthony R and Zannoni, Elena Maria},
  title = {Applications of Cd(Zn)Te Radiation Detectors in Non-Destructive Testing and Evaluation},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {6},
  pages = {1776},
  doi = {10.3390/s25061776}
}
Kostenlos starten →