TRCCBP: Transformer Network for Radar-Based Contactless Continuous Blood Pressure Monitoring
Sensors · 07.12.2023 · 23 (24) · 9680
DOI: 10.3390/s23249680 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 07.12.2023. Verfasst von Xikang Jiang und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100876, China. Hauptthemen laut MEDLINE: Radar, Photoplethysmography. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of China, Project, BUPT Excellent Ph.D. Students Foundation.
Abstract (Originalsprache)
Contactless continuous blood pressure (BP) monitoring is of great significance for daily healthcare. Radar-based continuous monitoring methods typically extract time-domain features manually such as pulse transit time (PTT) to calculate the BP. However, breathing and slight body movements usually distort the features extracted from pulse-wave signals, especially in long-term continuous monitoring, and manually extracted features may have limited performance for BP estimation. This article proposes a Transformer network for Radar-based Contactless Continuous Blood Pressure monitoring (TRCCBP). A heartbeat signal-guided single-beat pulse wave extraction method is designed to obtain pure pulse-wave signals. A transformer network-based blood pressure estimation network is proposed to estimate BP, which utilizes convolutional layers with different scales, a gated recurrent unit (GRU) to capture time-dependence in continuous radar signal and multi-head attention modules to capture deep temporal domain characteristics. A radar signal dataset captured in an indoor environment containing 31 persons and a real medical situation containing five persons is set up to evaluate the performance of TRCCBP. Compared with the state-of-the-art method, the average accuracy of diastolic blood pressure (DBP) and systolic blood pressure (SBP) is 4.49 mmHg and 4.73 mmHg, improved by 12.36 mmHg and 8.80 mmHg, respectively. The proposed TRCCBP source codes and radar signal dataset have been made open-source online for further research.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100876, China.
- Logistic Support Center, Chinese PLA General Hospital, Beijing 100853, China.
ORCID-Profile: Xikang Jiang, Lei Li
Förderung
- Natural Science Foundation of China
- Project
- BUPT Excellent Ph.D. Students Foundation
- LB2022B010100
Zitieren
APA
Jiang, X., Zhang, J., Mu, W., Wang, K., Li, L., & Zhang, L. (2023). TRCCBP: Transformer Network for Radar-Based Contactless Continuous Blood Pressure Monitoring. Sensors, 23(24), 9680. https://doi.org/10.3390/s23249680
Vancouver
Jiang X, Zhang J, Mu W, Wang K, Li L, Zhang L. TRCCBP: Transformer Network for Radar-Based Contactless Continuous Blood Pressure Monitoring. Sensors. 2023;23(24):9680. doi:10.3390/s23249680
BibTeX
@article{Jiang2023,
author = {Jiang, Xikang and Zhang, Jinhui and Mu, Wenyao and Wang, Kun and Li, Lei and Zhang, Lin},
title = {TRCCBP: Transformer Network for Radar-Based Contactless Continuous Blood Pressure Monitoring},
journal = {Sensors},
year = {2023},
volume = {23},
number = {24},
pages = {9680},
doi = {10.3390/s23249680}
}