EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

TRCCBP: Transformer Network for Radar-Based Contactless Continuous Blood Pressure Monitoring

Xikang Jiang iD, Jinhui Zhang, Wenyao Mu, Kun Wang, Lei Li iD, Lin Zhang

Sensors · 07.12.2023 · 23 (24) · 9680

DOI: 10.3390/s23249680 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 07.12.2023. Verfasst von Xikang Jiang und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100876, China. Hauptthemen laut MEDLINE: Radar, Photoplethysmography. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of China, Project, BUPT Excellent Ph.D. Students Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Contactless continuous blood pressure (BP) monitoring is of great significance for daily healthcare. Radar-based continuous monitoring methods typically extract time-domain features manually such as pulse transit time (PTT) to calculate the BP. However, breathing and slight body movements usually distort the features extracted from pulse-wave signals, especially in long-term continuous monitoring, and manually extracted features may have limited performance for BP estimation. This article proposes a Transformer network for Radar-based Contactless Continuous Blood Pressure monitoring (TRCCBP). A heartbeat signal-guided single-beat pulse wave extraction method is designed to obtain pure pulse-wave signals. A transformer network-based blood pressure estimation network is proposed to estimate BP, which utilizes convolutional layers with different scales, a gated recurrent unit (GRU) to capture time-dependence in continuous radar signal and multi-head attention modules to capture deep temporal domain characteristics. A radar signal dataset captured in an indoor environment containing 31 persons and a real medical situation containing five persons is set up to evaluate the performance of TRCCBP. Compared with the state-of-the-art method, the average accuracy of diastolic blood pressure (DBP) and systolic blood pressure (SBP) is 4.49 mmHg and 4.73 mmHg, improved by 12.36 mmHg and 8.80 mmHg, respectively. The proposed TRCCBP source codes and radar signal dataset have been made open-source online for further research.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadarPhotoplethysmographyBlood PressureBlood Pressure DeterminationMonitoring, PhysiologicPulse Wave Analysis

Stichwörter der Autor:innen

IR-UWB radarblood pressurecontactless continuous monitoringpulse wavetransformer

Autor:innen und Institutionen

  • School of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100876, China.
  • Logistic Support Center, Chinese PLA General Hospital, Beijing 100853, China.

ORCID-Profile: Xikang Jiang, Lei Li

Förderung

  • Natural Science Foundation of China
  • Project
  • BUPT Excellent Ph.D. Students Foundation
  • LB2022B010100

Zitieren

APA

Jiang, X., Zhang, J., Mu, W., Wang, K., Li, L., & Zhang, L. (2023). TRCCBP: Transformer Network for Radar-Based Contactless Continuous Blood Pressure Monitoring. Sensors, 23(24), 9680. https://doi.org/10.3390/s23249680

Vancouver

Jiang X, Zhang J, Mu W, Wang K, Li L, Zhang L. TRCCBP: Transformer Network for Radar-Based Contactless Continuous Blood Pressure Monitoring. Sensors. 2023;23(24):9680. doi:10.3390/s23249680

BibTeX
@article{Jiang2023,
  author = {Jiang, Xikang and Zhang, Jinhui and Mu, Wenyao and Wang, Kun and Li, Lei and Zhang, Lin},
  title = {TRCCBP: Transformer Network for Radar-Based Contactless Continuous Blood Pressure Monitoring},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {24},
  pages = {9680},
  doi = {10.3390/s23249680}
}