Multi-Signal Acquisition System for Continuous Blood Pressure Monitoring
Sensors · 2025
DOI: 10.3390/s25185910 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Naiwen Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen 518060, China. Hauptthemen laut MEDLINE: Blood Pressure, Blood Pressure Determination, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Shenzhen Medical Academy of Research and Translation, Shenzhen Medical Research Fund, Shenzhen Basic Research Program (Shenzhen Natural Science Foundation).
Abstract (Originalsprache)
Continuous blood pressure (BP) monitoring is essential for the early detection and prevention of cardiovascular diseases like hypertension. Recently, interest in continuous BP estimation systems and algorithms has grown. Various physiological signals reflect BP variations from different perspectives, and combining multiple signals can enhance the accuracy of BP measurements. However, research integrating electrocardiogram (ECG), photoplethysmography (PPG), and impedance cardiography (ICG) signals for BP monitoring remains limited, with related technologies still in early development. A major challenge is the increased system complexity associated with acquiring multiple signals simultaneously, along with the difficulty of efficiently extracting and integrating key features for accurate BP estimation. To address this, we developed a BP monitoring system that can synchronously acquire and process ECG, PPG, and ICG signals. Optimizing the circuit design allowed ECG and ICG modules to share electrodes, reducing components and improving compactness. Using this system, we collected 400 min of signals from 40 healthy subjects, yielding 4390 records. Experiments were conducted to evaluate the system’s performance in BP estimation. The results demonstrated that combining pulse wave analysis features with the XGBoost model yielded the most accurate BP predictions. Specifically, the mean absolute error for systolic blood pressure was 3.76 ± 3.98 mmHg, and for diastolic blood pressure, it was 2.71 ± 2.57 mmHg, both of which achieved grade A performance under the BHS standard. These results are comparable to or better than existing studies based on multi-signal methods. These findings suggest that the proposed system offers an efficient and practical solution for BP monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen 518060, China.
- Guangdong-Hongkong-Macau Institute of CNS Regeneration, Ministry of Education CNS Regeneration Collaborative Joint Laboratory, Jinan University, Guangzhou 510632, China.
- Center for Language and Brain, Shenzhen Institute of Neuroscience, Shenzhen 518057, China.
ORCID-Profile: Naiwen Zhang, Yu Zhang, Jintao Chen, Shaoxuan Qiu, Jinting Ma, Lihai Tan, Guo Dan
Förderung
- Shenzhen Medical Academy of Research and Translation
- Shenzhen Medical Research Fund
- Shenzhen Basic Research Program (Shenzhen Natural Science Foundation)
- Guangdong Basic and Applied Basic Research Foundation
Zitieren
APA
Zhang, N., Zhang, Y., Chen, J., Qiu, S., Ma, J., Tan, L., & Dan, G. (2025). Multi-Signal Acquisition System for Continuous Blood Pressure Monitoring. Sensors. https://doi.org/10.3390/s25185910
Vancouver
Zhang N, Zhang Y, Chen J, Qiu S, Ma J, Tan L, et al. Multi-Signal Acquisition System for Continuous Blood Pressure Monitoring. Sensors. 2025. doi:10.3390/s25185910
BibTeX
@article{Zhang2025,
author = {Zhang, Naiwen and Zhang, Yu and Chen, Jintao and Qiu, Shaoxuan and Ma, Jinting and Tan, Lihai and Dan, Guo},
title = {Multi-Signal Acquisition System for Continuous Blood Pressure Monitoring},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25185910}
}
EUVIMED