Accelerometric Classification of Resting and Postural Tremor Amplitude
Sensors · 21.10.2023 · 23 (20) · 8621
DOI: 10.3390/s23208621 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 21.10.2023. Verfasst von Christina van der Linden und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, University Hospital Cologne and Faculty of Medicine, University of Cologne, 50937 Cologne, Germany. Hauptthemen laut MEDLINE: Parkinson Disease, Essential Tremor. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, German Research Foundation, Koeln Fortune Program/Faculty of Medicine, University of Cologne.
Abstract (Originalsprache)
Clinical rating scales for tremors have significant limitations due to low resolution, high rater dependency, and lack of applicability in outpatient settings. Reliable, quantitative approaches for assessing tremor severity are warranted, especially evaluating treatment effects, e.g., of deep brain stimulation (DBS). We aimed to investigate how different accelerometry metrics can objectively classify tremor amplitude of Essential Tremor (ET) and tremor in Parkinson’s Disease (PD). We assessed 860 resting and postural tremor trials in 16 patients with ET and 25 patients with PD under different DBS settings. Clinical ratings were compared to different metrics, based on either spectral components in the tremorband or pure acceleration, derived from simultaneous triaxial accelerometry captured at the index finger and wrist. Nonlinear regression was applied to a training dataset to determine the relationship between accelerometry and clinical ratings, which was then evaluated in a holdout dataset. All of the investigated accelerometry metrics could predict clinical tremor ratings with a high concordance (>70%) and substantial interrater reliability (Cohen’s weighted Kappa > 0.7) in out-of-sample data. Finger-worn accelerometry performed slightly better than wrist-worn accelerometry. We conclude that triaxial accelerometry reliably quantifies resting and postural tremor amplitude in ET and PD patients. A full release of our dataset and software allows for implementation, development, training, and validation of novel methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurology, University Hospital Cologne and Faculty of Medicine, University of Cologne, 50937 Cologne, Germany.
- Department of Stereotactic and Functional Neurosurgery, University Hospital Cologne and Faculty of Medicine, University of Cologne, 50937 Cologne, Germany.
- Department of Psychiatry and Psychotherapy, University Hospital Cologne and Faculty of Medicine, University of Cologne, 50937 Cologne, Germany.
- Institute of Neuroscience and Medicine (INM-3), Forschungszentrum Jülich, 52428 Jülich, Germany.
ORCID-Profile: Christina van der Linden, Joshua N Strelow, Gereon R Fink, Till A Dembek
Förderung
- Deutsche Forschungsgemeinschaft
- German Research Foundation
- Koeln Fortune Program/Faculty of Medicine, University of Cologne
Zitieren
APA
van der Linden, C., Berger, T., Brandt, G. A., Strelow, J. N., Jergas, H., Baldermann, J. C., Visser-Vandewalle, V., Fink, G. R., Barbe, M. T., Petry-Schmelzer, J. N., & Dembek, T. A. (2023). Accelerometric Classification of Resting and Postural Tremor Amplitude. Sensors, 23(20), 8621. https://doi.org/10.3390/s23208621
Vancouver
van der Linden C, Berger T, Brandt GA, Strelow JN, Jergas H, Baldermann JC, et al. Accelerometric Classification of Resting and Postural Tremor Amplitude. Sensors. 2023;23(20):8621. doi:10.3390/s23208621
BibTeX
@article{vanderLinden2023,
author = {van der Linden, Christina and Berger, Thea and Brandt, Gregor A and Strelow, Joshua N and Jergas, Hannah and Baldermann, Juan Carlos and Visser-Vandewalle, Veerle and Fink, Gereon R and Barbe, Michael T and Petry-Schmelzer, Jan Niklas and Dembek, Till A},
title = {Accelerometric Classification of Resting and Postural Tremor Amplitude},
journal = {Sensors},
year = {2023},
volume = {23},
number = {20},
pages = {8621},
doi = {10.3390/s23208621}
}