EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Smart Watch Sensors for Tremor Assessment in Parkinson’s Disease—Algorithm Development and Measurement Properties Analysis

Giulia Palermo Schifino, Maira Jaqueline da Cunha, Ritchele Redivo Marchese iD, Vinicius Mabília iD, Luis Henrique Amoedo Vian, Francisca Dos Santos Pereira, Veronica Cimolin iD, Aline Souza Pagnussat iD

Sensors · 2025

DOI: 10.3390/s25144313 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Giulia Palermo Schifino und 7 weiteren Autor:innen. Beteiligte Einrichtung: Movement Analysis and Rehabilitation Laboratory, Universidade Federal de Ciências da Saúde de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil. Hauptthemen laut MEDLINE: Parkinson Disease, Tremor, Algorithms, Wearable Electronic Devices. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Parkinson’s disease (PD) is a neurodegenerative disorder commonly marked by upper limb tremors that interfere with daily activities. Wearable devices, such as smartwatches, represent a promising solution for continuous and objective monitoring in PD. This study aimed to develop and validate a tremor-detection algorithm using smartwatch sensors. Data were collected from 21 individuals with PD and 27 healthy controls using both a commercial inertial measurement unit (G-Sensor, BTS Bioengineering, Italy) and a smartwatch (Apple Watch Series 3). Participants performed standardized arm movements while sensor signals were synchronized and processed to extract relevant features. Statistical analyses assessed discriminant and concurrent validity, reliability, and accuracy. The algorithm demonstrated moderate to strong correlations between smartwatch and commercial IMU data, effectively distinguishing individuals with PD from healthy controls showing associations with clinical measures, such as the MDS-UPDRS III. Reliability analysis demonstrated agreement between repeated measurements, although a proportional bias was noted. Power spectral density (PSD) analysis of accelerometer and gyroscope data along the x-axis successfully detected the presence of tremors. These findings support the use of smartwatches as a tool for detecting tremors in PD. However, further studies involving larger and more clinically impaired samples are needed to confirm the robustness and generalizability of these results.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Parkinson DiseaseTremorAlgorithmsWearable Electronic DevicesHumansMaleFemaleMiddle AgedAgedAccelerometryReproducibility of Results

Stichwörter der Autor:innen

Parkinson’s diseaseinertial measurement unitmovement disordersmartwatchspectral analysistremorupper limbwearable sensors

Autor:innen und Institutionen

  • Movement Analysis and Rehabilitation Laboratory, Universidade Federal de Ciências da Saúde de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil.
  • Rehabilitation Sciences Graduate Program, Universidade Federal de Ciências da Saúde de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil.
  • Department of Physical Therapy, Universidade Federal de Ciências da Saúde de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil.
  • Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy.
  • IRCCS Istituto Auxologico Italiano, 28824 Piancavallo, Italy.
  • Health Sciences Graduate Program, Universidade Federal de Ciências da Saúde de Porto Alegre (UFCSPA), Porto Alegre 90050-170, Brazil.

ORCID-Profile: Ritchele Redivo Marchese, Vinicius Mabília, Veronica Cimolin, Aline Souza Pagnussat

Zitieren

APA

Schifino, G. P., da Cunha, M. J., Marchese, R. R., Mabília, V., Vian, L. H. A., Pereira, F. D. S., Cimolin, V., & Pagnussat, A. S. (2025). Smart Watch Sensors for Tremor Assessment in Parkinson’s Disease—Algorithm Development and Measurement Properties Analysis. Sensors. https://doi.org/10.3390/s25144313

Vancouver

Schifino GP, da Cunha MJ, Marchese RR, Mabília V, Vian LHA, Pereira FDS, et al. Smart Watch Sensors for Tremor Assessment in Parkinson’s Disease—Algorithm Development and Measurement Properties Analysis. Sensors. 2025. doi:10.3390/s25144313

BibTeX
@article{Schifino2025,
  author = {Schifino, Giulia Palermo and da Cunha, Maira Jaqueline and Marchese, Ritchele Redivo and Mabília, Vinicius and Vian, Luis Henrique Amoedo and Pereira, Francisca Dos Santos and Cimolin, Veronica and Pagnussat, Aline Souza},
  title = {Smart Watch Sensors for Tremor Assessment in Parkinson’s Disease—Algorithm Development and Measurement Properties Analysis},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25144313}
}
Kostenlos starten →