EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Highly Repeatable Fibrous Crack‐Based Strain Sensor for Multichannel Continuous Tremor Monitoring in Parkinson's Disease and Essential Tremor

Chiwon Song iD, Chan Park iD, Juyoun Lee iD, Hojoong Kim, Jeongbeom Kang iD, Byeongjun Lee iD, Cheoljeong Park iD, Jungmin Kim iD, Haran Lee iD, Yoon Jae Lee iD, Min-Kyung Yeo iD, Woon-Hong Yeo iD und 1 weitere

Advanced Science · 2026

DOI: 10.1002/advs.76724 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Science, 2026. Verfasst von Chiwon Song und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Chungnam National University (CNU), Daejeon, Republic of Korea. Hauptthemen laut MEDLINE: Parkinson Disease, Essential Tremor, Wireless Technology, Tremor. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Institute for Advancement of Technology, Institute of Information & Communications Technology Planning & Evaluation, National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective measurement of tremors is important for assessing the severity and preventing misdiagnosis of Parkinson's disease (PD). To address this demand, this study presents a multichannel, wireless, patch‐type tremor monitoring system that integrates a high‐repeatable fibrous crack‐based strain (FCBS) sensor with a flexible wireless communication circuit. The FCBS sensor, incorporating crack structures, random fiber orientation, junction melting, and polymer penetration within a 3D conductive fiber network, achieves high sensitivity (gauge factor up to 476.89), a fast response time (≈ 6.64 ms), a wide working range (>200% strain), low Young's modulus (≈45 kPa), and excellent repeatability (>100 000 cycles). In addition, this study demonstrates the first clinical application of a flexible strain sensor‐based tremor monitoring system in patients with PD and ET for simultaneous multilocation tremor measurement. Through clinical trials, our system measured tremor indicators (peak amplitude and fundamental frequency), and tremor indicators obtained from multilocation showed improved correlation and statistical significance with tremor scoring in UPDRS III under specific conditions. These results demonstrate the applicability and potential of the flexible strain sensor‐based system as a wearable platform for quantitative and objective tremor measurement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Parkinson DiseaseEssential TremorWireless TechnologyTremorHumansEquipment DesignMonitoring, PhysiologicWearable Electronic DevicesReproducibility of Results

Stichwörter der Autor:innen

Parkinson's diseaseessential tremorfibrous crack‐based strain sensortremor monitoring system

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Chungnam National University (CNU), Daejeon, Republic of Korea.
  • National NanoFab Center (NNFC), Daejeon, Republic of Korea.
  • Department of Neurology, Chungnam National University School of Medicine, Daejeon, Republic of Korea.
  • George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA.
  • Wearable Intelligent Systems and Healthcare Center (WISH Center) At the Institute for Matter and Systems, Georgia Institute of Technology, Atlanta, Georgia, USA.
  • School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA.

ORCID-Profile: Chiwon Song, Chan Park, Juyoun Lee, Jeongbeom Kang, Byeongjun Lee, Cheoljeong Park, Jungmin Kim, Haran Lee, Yoon Jae Lee, Min-Kyung Yeo, Woon-Hong Yeo, Seong J Cho

Förderung

  • Korea Institute for Advancement of Technology
  • Institute of Information & Communications Technology Planning & Evaluation
  • National Research Foundation of Korea
  • Chungnam National University
  • BK21 FOUR Program by Chungnam National University Research Grant
  • Georgia Tech Institute for Matter and Systems
  • Global Industrial Technology Cooperation Center
  • National Science Foundation Research Traineeship

Zitieren

APA

Song, C., Park, C., Lee, J., Kim, H., Kang, J., Lee, B., Park, C., Kim, J., Lee, H., Lee, Y. J., Yeo, M. K., Yeo, W. H., & Cho, S. J. (2026). Highly Repeatable Fibrous Crack‐Based Strain Sensor for Multichannel Continuous Tremor Monitoring in Parkinson's Disease and Essential Tremor. Advanced Science. https://doi.org/10.1002/advs.76724

Vancouver

Song C, Park C, Lee J, Kim H, Kang J, Lee B, et al. Highly Repeatable Fibrous Crack‐Based Strain Sensor for Multichannel Continuous Tremor Monitoring in Parkinson's Disease and Essential Tremor. Advanced Science. 2026. doi:10.1002/advs.76724

BibTeX
@article{Song2026,
  author = {Song, Chiwon and Park, Chan and Lee, Juyoun and Kim, Hojoong and Kang, Jeongbeom and Lee, Byeongjun and Park, Cheoljeong and Kim, Jungmin and Lee, Haran and Lee, Yoon Jae and Yeo, Min-Kyung and Yeo, Woon-Hong and Cho, Seong J},
  title = {Highly Repeatable Fibrous Crack‐Based Strain Sensor for Multichannel Continuous Tremor Monitoring in Parkinson's Disease and Essential Tremor},
  journal = {Advanced Science},
  year = {2026},
  doi = {10.1002/advs.76724}
}
Kostenlos starten →