A Modular 3-Degrees-of-Freedom Force Sensor for Robot-Assisted Minimally Invasive Surgery Research
Sensors · 2023
DOI: 10.3390/s23115230 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Zonghe Chua und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical, Computer and Systems Engineering, Case Western Reserve University, 10900 Euclid Avenue, Glennan Building 514A, Cleveland, O…. Hauptthemen laut MEDLINE: Robotics, Robotic Surgical Procedures. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National University of Singapore, Stanford University, Stanford Bio-X Fellowship.
Abstract (Originalsprache)
Effective force modulation during tissue manipulation is important for ensuring safe, robot-assisted, minimally invasive surgery (RMIS). Strict requirements for in vivo applications have led to prior sensor designs that trade off ease of manufacture and integration against force measurement accuracy along the tool axis. Due to this trade-off, there are no commercial, off-the-shelf, 3-degrees-of-freedom (3DoF) force sensors for RMIS available to researchers. This makes it challenging to develop new approaches to indirect sensing and haptic feedback for bimanual telesurgical manipulation. We present a modular 3DoF force sensor that integrates easily with an existing RMIS tool. We achieve this by relaxing biocompatibility and sterilizability requirements and by using commercial load cells and common electromechanical fabrication techniques. The sensor has a range of ±5 N axially and ±3 N laterally with errors of below 0.15 N and maximum errors below 11% of the sensing range in all directions. During telemanipulation, a pair of jaw-mounted sensors achieved average errors below 0.15 N in all directions. It achieved an average grip force error of 0.156 N. The sensor is for bimanual haptic feedback and robotic force control in delicate tissue telemanipulation. As an open-source design, the sensors can be adapted to suit other non-RMIS robotic applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical, Computer and Systems Engineering, Case Western Reserve University, 10900 Euclid Avenue, Glennan Building 514A, Cleveland, OH 44106, USA.
- Department of Mechanical Engineering, Stanford University, Stanford, CA 94305, USA.
ORCID-Profile: Zonghe Chua, Allison M Okamura
Förderung
- National University of Singapore
- Stanford University
- Stanford Bio-X Fellowship
- National University of Singapore Development Grant
Zitieren
APA
Chua, Z., & Okamura, A. M. (2023). A Modular 3-Degrees-of-Freedom Force Sensor for Robot-Assisted Minimally Invasive Surgery Research. Sensors. https://doi.org/10.3390/s23115230
Vancouver
Chua Z, Okamura AM. A Modular 3-Degrees-of-Freedom Force Sensor for Robot-Assisted Minimally Invasive Surgery Research. Sensors. 2023. doi:10.3390/s23115230
BibTeX
@article{Chua2023,
author = {Chua, Zonghe and Okamura, Allison M},
title = {A Modular 3-Degrees-of-Freedom Force Sensor for Robot-Assisted Minimally Invasive Surgery Research},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23115230}
}
EUVIMED