Phase-Resolved Optical Coherence Elastography: An Insight into Tissue Displacement Estimation
Sensors · 2023
DOI: 10.3390/s23083974 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Ana Batista und 9 weiteren Autor:innen. Beteiligte Einrichtung: Coimbra Institute for Biomedical Imaging and Translational Research (CIBIT), Institute for Nuclear Sciences Applied to Health (ICNAS), University of …. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Elasticity Imaging Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: FEDER Funds, Fundação para a Ciência e Tecnologia, Portuguese Foundation for Science and Technology (FCT).
Abstract (Originalsprache)
Robust methods to compute tissue displacements in optical coherence elastography (OCE) data are paramount, as they play a significant role in the accuracy of tissue elastic properties estimation. In this study, the accuracy of different phase estimators was evaluated on simulated OCE data, where the displacements can be accurately set, and on real data. Displacement (∆d) estimates were computed from (i) the original interferogram data (Δφori) and two phase-invariant mathematical manipulations of the interferogram: (ii) its first-order derivative (Δφd) and (iii) its integral (Δφint). We observed a dependence of the phase difference estimation accuracy on the initial depth location of the scatterer and the magnitude of the tissue displacement. However, by combining the three phase-difference estimates (Δdav), the error in phase difference estimation could be minimized. By using Δdav, the median root-mean-square error associated with displacement prediction in simulated OCE data was reduced by 85% and 70% in data with and without noise, respectively, in relation to the traditional estimate. Furthermore, a modest improvement in the minimum detectable displacement in real OCE data was also observed, particularly in data with low signal-to-noise ratios. The feasibility of using Δdav to estimate agarose phantoms’ Young’s modulus is illustrated.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Coimbra Institute for Biomedical Imaging and Translational Research (CIBIT), Institute for Nuclear Sciences Applied to Health (ICNAS), University of Coimbra, 3000-548 Coimbra, Portugal.
- Department of Physics, Faculty of Science and Technology, University of Coimbra, 3004-531 Coimbra, Portugal.
- Department of Science and Technology, Mathematics Section, Aberta University, 1250-100 Lisbon, Portugal.
- Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Coimbra, 3004-531 Coimbra, Portugal.
- Department of Mathematics, CMUC, University of Coimbra, 3004-531 Coimbra, Portugal.
- Faculty of Medicine (FMUC), Clinical Academic Center of Coimbra (CACC), University of Coimbra, 3000-143 Coimbra, Portugal.
ORCID-Profile: Ana Batista, Mário J Santos, Miguel Morgado, Rui Bernardes
Förderung
- FEDER Funds
- Fundação para a Ciência e Tecnologia
- Portuguese Foundation for Science and Technology (FCT)
Zitieren
APA
Batista, A., Serranho, P., Santos, M. J., Correia, C., Domingues, J. P., Loureiro, C., Cardoso, J., Barbeiro, S., Morgado, M., & Bernardes, R. (2023). Phase-Resolved Optical Coherence Elastography: An Insight into Tissue Displacement Estimation. Sensors. https://doi.org/10.3390/s23083974
Vancouver
Batista A, Serranho P, Santos MJ, Correia C, Domingues JP, Loureiro C, et al. Phase-Resolved Optical Coherence Elastography: An Insight into Tissue Displacement Estimation. Sensors. 2023. doi:10.3390/s23083974
BibTeX
@article{Batista2023,
author = {Batista, Ana and Serranho, Pedro and Santos, Mário J and Correia, Carlos and Domingues, José P and Loureiro, Custódio and Cardoso, João and Barbeiro, Sílvia and Morgado, Miguel and Bernardes, Rui},
title = {Phase-Resolved Optical Coherence Elastography: An Insight into Tissue Displacement Estimation},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23083974}
}