EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Determinants of Human Corneal Mechanical Wave Dispersion for In Vivo Optical Coherence Elastography

Chaitanya Duvvuri, Manmohan Singh, Gongpu Lan, Salavat R Aglyamov, Kirill V Larin, Michael D Twa

Translational Vision Science & Technology · 2025

DOI: 10.1167/tvst.14.1.26 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational Vision Science & Technology, 2025. Verfasst von Chaitanya Duvvuri und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Optometry, University of Houston, Houston, TX, USA. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Cornea, Tomography, Optical Coherence. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 73 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To characterize frequency-dependent wave speed dispersion in the human cornea using microliter air-pulse optical coherence elastography (OCE), and to evaluate the applicability of Lamb wave theory for determining corneal elastic modulus using high-frequency symmetric (S0) and anti-symmetric (A0) guided waves in cornea.

Methods

Wave speed dispersion analysis for transient (0.5 ms) microliter air-pulse stimulation was performed in four rabbit eyes ex vivo and compared to air-coupled ultrasound excitation. The effects of stimulation angle and sample geometry on the dispersion were evaluated in corneal phantoms. Corneal wave speed dispersion was measured in 36 healthy human eyes in vivo.

Results

Air-pulse-induced dispersion was comparable to ultrasound-induced dispersion between 0.7 and 5 kHz (mean-difference ± 1.96 × SD: 0.006 ± 0.5 m/s) in ex vivo rabbit corneas. Stimulation 0° relative to the surface normal generated A0 Lamb waves in corneal tissue phantoms, while oblique stimulation (35° and 65°) generated S0 waves. Stimulating normal to the human corneal apex in vivo (0°) induced A0 waves, plateauing at 10.87 to 13.63 m/s at 4 kHz, and when obliquely stimulated at the periphery (65°), produced S0 waves, plateauing at 13.10 to 15.98 m/s at 4 kHz.

Conclusions

Air-pulse OCE can be used to measure human corneal Lamb wave dispersion of A0 and S0 propagation modes in vivo. These modes are selectively excited by changing the stimulation angle. Accounting for wave speed dispersion enables reliable estimation of corneal elastic modulus in vivo. Translational Relevance: This work demonstrates the feasibility of air-pulse stimulation for robust OCE measurements of corneal stiffness in vivo for disease detection and therapy evaluation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesCorneaTomography, Optical CoherenceHumansRabbitsAnimalsElastic ModulusMaleAdultFemalePhantoms, ImagingMiddle Aged

Autor:innen und Institutionen

  • College of Optometry, University of Houston, Houston, TX, USA.
  • Department of Biomedical Engineering, University of Houston, Houston, TX, USA.
  • School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong, China.
  • Department of Mechanical Engineering, University of Houston, Houston, TX, USA.

Förderung

  • NEI NIH HHS

Zitieren

APA

Duvvuri, C., Singh, M., Lan, G., Aglyamov, S. R., Larin, K. V., & Twa, M. D. (2025). Determinants of Human Corneal Mechanical Wave Dispersion for In Vivo Optical Coherence Elastography. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.14.1.26

Vancouver

Duvvuri C, Singh M, Lan G, Aglyamov SR, Larin KV, Twa MD. Determinants of Human Corneal Mechanical Wave Dispersion for In Vivo Optical Coherence Elastography. Translational Vision Science & Technology. 2025. doi:10.1167/tvst.14.1.26

BibTeX
@article{Duvvuri2025,
  author = {Duvvuri, Chaitanya and Singh, Manmohan and Lan, Gongpu and Aglyamov, Salavat R and Larin, Kirill V and Twa, Michael D},
  title = {Determinants of Human Corneal Mechanical Wave Dispersion for In Vivo Optical Coherence Elastography},
  journal = {Translational Vision Science & Technology},
  year = {2025},
  doi = {10.1167/tvst.14.1.26}
}
Kostenlos starten →