EUVIMEDEUVIMED entdecken
Crossref

Ultrashort echo time magnetic resonance elastography for quantification of the mechanical properties of short T2 tissues via optimal control‐based radiofrequency pulses

Pilar Sango-Solanas, Kevin Tse Ve Koon, Eric Van Reeth, Stéphane Nicolle, Jean-François Palierne, Cyrielle Caussy, Olivier Beuf

NMR in Biomedicine · 2024

DOI: 10.1002/nbm.5210 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2024. Verfasst von Pilar Sango-Solanas und 6 weiteren Autor:innen. Beteiligte Einrichtung: Univ Lyon, INSA-Lyon, Inserm, UCBL1, CNRS, CREATIS, UMR 5220, U1294, Villeurbanne, France. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Radio Waves, Phantoms, Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 60 Literaturangaben. Gefördert von: French National Research Agency, Agence Nationale de la Recherche.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of the current study is to demonstrate the feasibility of radiofrequency (RF) pulses generated via an optimal control (OC) algorithm to perform magnetic resonance elastography (MRE) and quantify the mechanical properties of materials with very short transverse relaxation times (T2 < 5 ms) for the first time. OC theory applied to MRE provides RF pulses that bring isochromats from the equilibrium state to a fixed target state, which corresponds to the phase pattern of a conventional MRE acquisition. Such RF pulses applied with a constant gradient allow to simultaneously perform slice selection and motion encoding in the slice direction. Unlike conventional MRE, no additional motion‐encoding gradients (MEGs) are needed, enabling shorter echo times. OC pulses were implemented both in turbo spin echo (OC rapid acquisition with refocused echoes [RARE]) and ultrashort echo time (OC UTE) sequences to compare their motion‐encoding efficiency with the conventional MEG encoding (classical MEG MRE). MRE experiments were carried out on agar phantoms with very short T2 values and on an ex vivo bovine tendon. Magnitude images, wave field images, phase‐to‐noise ratio (PNR), and shear storage modulus maps were compared between OC RARE, OC UTE, and classical MEG MRE in samples with different T2 values. Shear storage modulus values of the agar phantoms were in agreement with values found in the literature, and that of the bovine tendon was corroborated with rheometry measurements. Only the OC sequences could encode motion in very short T2 samples, and only OC UTE sequences yielded magnitude images enabling proper visualization of short T2 samples and tissues. The OC UTE sequence produced the best PNRs, demonstrating its ability to perform anatomical and mechanical characterization. Its success warrants in vivo confirmation in further studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesRadio WavesPhantoms, ImagingAnimalsCattleTendonsAlgorithmsTime FactorsMagnetic Resonance ImagingElastic Modulus

Stichwörter der Autor:innen

MR elastographyRF pulse designoptimal control theoryshort T2tendon

Autor:innen und Institutionen

  • Univ Lyon, INSA-Lyon, Inserm, UCBL1, CNRS, CREATIS, UMR 5220, U1294, Villeurbanne, France.
  • CPE Lyon, Département Sciences du Numérique, Lyon, France.
  • Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR_T 9406, Lyon, France.
  • École Normale Supérieure de Lyon, CNRS, UMR 5672, Laboratoire de Physique, Lyon, France.
  • Univ Lyon, CarMen Laboratory, INSERM, INRA, INSA Lyon, Université Claude Bernard Lyon 1, Pierre-Bénite, France.
  • Hospices Civils de Lyon, Département Endocrinologie, Diabète et Nutrition, Hôpital Lyon Sud, Pierre-Bénite, France.

Förderung

  • French National Research Agency
  • Agence Nationale de la Recherche

Zitieren

APA

Sango-Solanas, P., Tse Ve Koon, K., Van Reeth, E., Nicolle, S., Palierne, J. F., Caussy, C., & Beuf, O. (2024). Ultrashort echo time magnetic resonance elastography for quantification of the mechanical properties of short T2 tissues via optimal control‐based radiofrequency pulses. NMR in Biomedicine. https://doi.org/10.1002/nbm.5210

Vancouver

Sango-Solanas P, Tse Ve Koon K, Van Reeth E, Nicolle S, Palierne JF, Caussy C, et al. Ultrashort echo time magnetic resonance elastography for quantification of the mechanical properties of short T2 tissues via optimal control‐based radiofrequency pulses. NMR in Biomedicine. 2024. doi:10.1002/nbm.5210

BibTeX
@article{SangoSolanas2024,
  author = {Sango-Solanas, Pilar and Tse Ve Koon, Kevin and Van Reeth, Eric and Nicolle, Stéphane and Palierne, Jean-François and Caussy, Cyrielle and Beuf, Olivier},
  title = {Ultrashort echo time magnetic resonance elastography for quantification of the mechanical properties of short T2 tissues via optimal control‐based radiofrequency pulses},
  journal = {NMR in Biomedicine},
  year = {2024},
  doi = {10.1002/nbm.5210}
}
Kostenlos starten →