EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Photoplethysmography Signal Wavelet Enhancement and Novel Features Selection for Non-Invasive Cuff-Less Blood Pressure Monitoring

Filippo Attivissimo iD, Luisa De Palma iD, Attilio Di Nisio iD, Marco Scarpetta iD, Anna Maria Lucia Lanzolla

Sensors · 19.02.2023 · 23 (4) · 2321

DOI: 10.3390/s23042321 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 19.02.2023. Verfasst von Filippo Attivissimo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Information Engineering, Polytechnic University of Bari, 70125 Bari, Italy. Hauptthemen laut MEDLINE: Photoplethysmography, Algorithms. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this paper, new features relevant to blood pressure (BP) estimation using photoplethysmography (PPG) are presented. A total of 195 features, including the proposed ones and those already known in the literature, have been calculated on a set composed of 50,000 pulses from 1080 different patients. Three feature selection methods, namely Correlation-based Feature Selection (CFS), RReliefF and Minimum Redundancy Maximum Relevance (MRMR), have then been applied to identify the most significant features for BP estimation. Some of these features have been extracted through a novel PPG signal enhancement method based on the use of the Maximal Overlap Discrete Wavelet Transform (MODWT). As a matter of fact, the enhanced signal leads to a reliable identification of the characteristic points of the PPG signal (e.g., systolic, diastolic and dicrotic notch points) by simple means, obtaining results comparable with those from purposely defined algorithms. For systolic points, mean and std of errors computed as the difference between the locations obtained using a purposely defined already known algorithm and those using the MODWT enhancement are, respectively, 0.0097 s and 0.0202 s; for diastolic points they are, respectively, 0.0441 s and 0.0486 s; for dicrotic notch points they are 0.0458 s and 0.0896 s. Hence, this study leads to the selection of several new features from the MODWT enhanced signal on every single pulse extracted from PPG signals, in addition to features already known in the literature. These features can be employed to train machine learning (ML) models useful for estimating systolic blood pressure (SBP) and diastolic blood pressure (DBP) in a non-invasive way, which is suitable for telemedicine health-care monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotoplethysmographyAlgorithmsHumansBlood PressureDiastoleHeart Rate

Stichwörter der Autor:innen

blood pressure (BP)features selectionhypertensionmaximal overlap discrete wavelet transform (MODWT)photoplethysmography (PPG)telemedicine

Autor:innen und Institutionen

  • Department of Electrical and Information Engineering, Polytechnic University of Bari, 70125 Bari, Italy.

ORCID-Profile: Filippo Attivissimo, Luisa De Palma, Attilio Di Nisio, Marco Scarpetta

Zitieren

APA

Attivissimo, F., De Palma, L., Di Nisio, A., Scarpetta, M., & Lanzolla, A. M. L. (2023). Photoplethysmography Signal Wavelet Enhancement and Novel Features Selection for Non-Invasive Cuff-Less Blood Pressure Monitoring. Sensors, 23(4), 2321. https://doi.org/10.3390/s23042321

Vancouver

Attivissimo F, De Palma L, Di Nisio A, Scarpetta M, Lanzolla AML. Photoplethysmography Signal Wavelet Enhancement and Novel Features Selection for Non-Invasive Cuff-Less Blood Pressure Monitoring. Sensors. 2023;23(4):2321. doi:10.3390/s23042321

BibTeX
@article{Attivissimo2023,
  author = {Attivissimo, Filippo and De Palma, Luisa and Di Nisio, Attilio and Scarpetta, Marco and Lanzolla, Anna Maria Lucia},
  title = {Photoplethysmography Signal Wavelet Enhancement and Novel Features Selection for Non-Invasive Cuff-Less Blood Pressure Monitoring},
  journal = {Sensors},
  year = {2023},
  volume = {23},
  number = {4},
  pages = {2321},
  doi = {10.3390/s23042321}
}
Kostenlos starten →