Automated Multi-Wavelength Quality Assessment of Photoplethysmography Signals Using Modulation Spectrum Shape Features
Sensors · 2023
DOI: 10.3390/s23125606 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Abhishek Tiwari und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institut National de la Recherche Scientifique, University of Quebec, Montreal, QC H5A 1K6, Canada. Hauptthemen laut MEDLINE: Photoplethysmography, Wearable Electronic Devices. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: MITACS.
Abstract (Originalsprache)
Photoplethysmography (PPG) is used to measure blood volume changes in the microvascular bed of tissue. Information about these changes along time can be used for estimation of various physiological parameters, such as heart rate variability, arterial stiffness, and blood pressure, to name a few. As a result, PPG has become a popular biological modality and is widely used in wearable health devices. However, accurate measurement of various physiological parameters requires good-quality PPG signals. Therefore, various signal quality indexes (SQIs) for PPG signals have been proposed. These metrics have usually been based on statistical, frequency, and/or template analyses. The modulation spectrogram representation, however, captures the second-order periodicities of a signal and has been shown to provide useful quality cues for electrocardiograms and speech signals. In this work, we propose a new PPG quality metric based on properties of the modulation spectrum. The proposed metric is tested using data collected from subjects while they performed various activity tasks contaminating the PPG signals. Experiments on this multi-wavelength PPG dataset show the combination of proposed and benchmark measures significantly outperforming several benchmark SQIs with improvements of 21.3% BACC (balanced accuracy) for green, 21.6% BACC for red, and 19.0% BACC for infrared wavelengths, respectively, for PPG quality detection tasks. The proposed metrics also generalize for cross-wavelength PPG quality detection tasks.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institut National de la Recherche Scientifique, University of Quebec, Montreal, QC H5A 1K6, Canada.
- Myant Inc., Toronto, ON M9W 5Z9, Canada.
ORCID-Profile: Amin Mahnam, Tiago H Falk
Förderung
- MITACS
Zitieren
APA
Tiwari, A., Gray, G., Bondi, P., Mahnam, A., & Falk, T. H. (2023). Automated Multi-Wavelength Quality Assessment of Photoplethysmography Signals Using Modulation Spectrum Shape Features. Sensors. https://doi.org/10.3390/s23125606
Vancouver
Tiwari A, Gray G, Bondi P, Mahnam A, Falk TH. Automated Multi-Wavelength Quality Assessment of Photoplethysmography Signals Using Modulation Spectrum Shape Features. Sensors. 2023. doi:10.3390/s23125606
BibTeX
@article{Tiwari2023,
author = {Tiwari, Abhishek and Gray, Gordon and Bondi, Parker and Mahnam, Amin and Falk, Tiago H},
title = {Automated Multi-Wavelength Quality Assessment of Photoplethysmography Signals Using Modulation Spectrum Shape Features},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23125606}
}
EUVIMED