Toward Ambulatory Baroreflex Sensitivity: Comparison Between Indices of Arterial Line and Photoplethysmography in Male Volunteers
JMIR Cardio · 17.07.2025 · 9 · e54771-e54771
DOI: 10.2196/54771 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift JMIR Cardio, online erschienen am 17.07.2025. Verfasst von Jolanda Witteveen und 2 weiteren Autor:innen. Beteiligte Einrichtung: One Planet Research Center, imec, Wageningen, The Netherlands. Hauptthemen laut MEDLINE: Photoplethysmography, Baroreflex, Heart Rate, Blood Pressure. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Baroreflex sensitivity (BRS) is the body’s ability to adjust heart rate (HR) to control blood pressure. Traditionally, BRS is quantified by measuring HR changes (obtained via an electrocardiogram [ECG]) following alterations in arterial pressure (conventionally measured through an arterial line). However, the invasiveness of arterial line necessitates alternatives, such as the volume clamp method and the less invasive pulse photoplethysmography (PPG). Notably, the PPG method is also suitable for continuous and free-living conditions.
Objective
This study aims to compare PPG-based features for BRS determination based on the volume clamp method and gold standard arterial line. Data from a previous study was used where the primary analysis focused on evaluating the accuracy of PPG-derived HR variability, while this analysis quantifies BRS by measuring HR changes following alterations in arterial line pressure or less invasive alternatives. In addition, we investigate the feasibility of assessing BRS patterns over 24 hours using data from a single volunteer.
Methods
A total of 28 male volunteers (age 52, SD 7 y; BMI 27, SD 4 kg/m 2 ) equipped with four sensing modalities: (1) arterial line [ABP], (2) infrared PPG, (3) volume clamp finger pressure (VCP), and (4) ECG, performed a protocol of 3 repetitive sessions in supine position. For the extended feasibility of continuous BRS measurement, ECG and PPG data were acquired for 24 hours in free-living conditions from a normotensive male volunteer (33 y). BRS index was calculated within the low-frequency window (0.04‐0.15 Hz) averaging over all trials for each intervention and participant. A transfer function was estimated with systolic blood pressure (SBP) or its surrogate as input and HR (from the ECG) as output.
Results
PPG-based BRS features, specifically the rise-decay time ratio (RDRatio) and pulse arrival time (PAT), demonstrate intraparticipant precision of 44% and 23%, respectively, with interparticipant variation of 91% and 53%. The correlation of BRS PAT,PPG and BRS RDRatio,PPG with the gold standard BRS SBP,ABP (SBP) is 0.66 and 0.56, respectively. During intervention, the correlations remain high for BRS RDRatio,PPG (rest: 0.75, paced-breathing: 0.50, and handgrip: 0.46) and BRS PAT,PPG (rest: 0.69, paced-breathing: 0.52, and handgrip: 0.62). In the 24-hour data, the BRS PAT,PPG and BRS RDRatio,PPG exhibit changes during the day corresponding to the activity levels and SBP variations. Notably, during the night, a cyclic rhythm is observed for both BRS PAT,PPG and BRS RDRatio,PPG .
Conclusions
This study demonstrates that in male volunteers, PPG-based PAT and RDRatio BRS serve as suitable surrogates for gold-standard BRS derived from arterial line, showing the highest correlation and comparable intraparticipant coefficient variation. Furthermore, they show expected changes during controlled activities and a 24-hour feasibility test in free-living conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- One Planet Research Center, imec, Wageningen, The Netherlands.
- imec The Netherlands/Holst Centre, High Tech Campus 31, Eindhoven, 5656 AE, The Netherlands.
Zitieren
APA
Witteveen, J., Beutel, F., & Hermeling, E. (2025). Toward Ambulatory Baroreflex Sensitivity: Comparison Between Indices of Arterial Line and Photoplethysmography in Male Volunteers. JMIR Cardio, 9, e54771-e54771. https://doi.org/10.2196/54771
Vancouver
Witteveen J, Beutel F, Hermeling E. Toward Ambulatory Baroreflex Sensitivity: Comparison Between Indices of Arterial Line and Photoplethysmography in Male Volunteers. JMIR Cardio. 2025;9:e54771-e54771. doi:10.2196/54771
BibTeX
@article{Witteveen2025,
author = {Witteveen, Jolanda and Beutel, Fabian and Hermeling, Evelien},
title = {Toward Ambulatory Baroreflex Sensitivity: Comparison Between Indices of Arterial Line and Photoplethysmography in Male Volunteers},
journal = {JMIR Cardio},
year = {2025},
volume = {9},
pages = {e54771--e54771},
doi = {10.2196/54771}
}
EUVIMED