A THD-Based Fault Protection Method Using MSOGI-FLL Grid Voltage Estimator
Sensors · 2023
DOI: 10.3390/s23020980 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Wael Al Hanaineh und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electric Engineering, Polytechnic University of Catalonia (EEBE-UPC), 08019 Barcelona, Spain. Hauptthemen laut MEDLINE: Algorithms, Communication. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The rapid growth of the distributed generators (DGs) integration into the distribution systems (DSs) creates new technical issues; conventional relay settings need to be updated depending on the network topology and operational mode as fault protection a major challenge. This emphasizes the need for new fault protection methods to ensure secure protection and prevent undesirable tripping. Total harmonic distortion (THD) is an important indicator for assessing the quality of the grid. Here, a new protection system based on the THD of the grid voltages is proposed to address fault events in the electrical distribution network. The proposed protection system combines the THD with the estimates of the amplitude voltages and the zero-sequence component for defining an algorithm based on a finite state machine (FSM) for the detection, identification, and isolation of faults in the grid. The algorithm employs communication lines between all the protective devices (PDs) of the system to transmit tripping signals, allowing PDs to be coordinated. A second order generalized integrator (SOGI) and multiple SOGI (MSOGI) are used to obtain the THDs, estimated amplitude voltages, and zero-sequence component, which allows for fast detection with a low computational burden. The protection algorithm performance is evaluated through simulations in MATLAB/Simulink and a comparative study is developed between the proposed protection method and a differential relay (DR) protection system. The proposed method shows its capability to detect and isolate faults during different fault types with different fault resistances in different locations in the proposed network. In all the tested scenarios, the detection time of the faults has been between 7–10 ms. Moreover, this method gave the best solution as it has a higher accuracy and faster response than the conventional DR protection system.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electric Engineering, Polytechnic University of Catalonia (EEBE-UPC), 08019 Barcelona, Spain.
- Department of Energy Technology, Aalborg University, 9200 Aalborg, Denmark.
- Department of Electrical Engineering, Polytechnic University of Catalonia, 08222 Terrassa, Spain.
ORCID-Profile: Wael Al Hanaineh, Jose Matas, Jorge El Mariachet, Mostafa Bakkar, Josep M Guerrero
Zitieren
APA
Al Hanaineh, W., Matas, J., El Mariachet, J., Xie, P., Bakkar, M., & Guerrero, J. M. (2023). A THD-Based Fault Protection Method Using MSOGI-FLL Grid Voltage Estimator. Sensors. https://doi.org/10.3390/s23020980
Vancouver
Al Hanaineh W, Matas J, El Mariachet J, Xie P, Bakkar M, Guerrero JM. A THD-Based Fault Protection Method Using MSOGI-FLL Grid Voltage Estimator. Sensors. 2023. doi:10.3390/s23020980
BibTeX
@article{AlHanaineh2023,
author = {Al Hanaineh, Wael and Matas, Jose and El Mariachet, Jorge and Xie, Peilin and Bakkar, Mostafa and Guerrero, Josep M},
title = {A THD-Based Fault Protection Method Using MSOGI-FLL Grid Voltage Estimator},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23020980}
}
EUVIMED