Hygrothermal Stress Analysis of Epoxy Molding Compound in Fan-Out Panel-Level Package Based on Experimental Characterization and Structural Sensitivity

Yu-Chi Sung, Chih-Ping Hu, Sheng-Jye Hwang, Ming-Hsien Shih, Wen-Hsiang Liao, Yong-Jie Zeng, Cheng-Tse Tsai iD

Polymers · 25.07.2025 · 17 (15) · 2034

DOI: 10.3390/polym17152034 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Polymers, online erschienen am 25.07.2025. Verfasst von Yu-Chi Sung und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, National Cheng Kung University, Tainan 70101, Taiwan. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As semiconductor devices demand higher input–output density and faster signal transmission, fan-out panel-level packaging has emerged as a promising solution for next-generation electronic systems. However, the hygroscopic nature of epoxy molding compounds raises critical reliability concerns under high-temperature and high-humidity conditions. This study investigates the hygrothermal stress of a single fan-out panel-level package unit through experimental characterization and numerical simulation. Thermal–mechanical analysis was conducted at 100 °C and 260 °C to evaluate the strain behavior of two commercial epoxy molding compounds in granule form after moisture saturation. The coefficient of moisture expansion was calculated by correlating strain variation with moisture uptake obtained under 85 °C and 85% relative humidity, corresponding to moisture sensitivity level 1 conditions. These values were directly considered into a moisture -thermal coupled finite element analysis. The simulation results under reflow conditions demonstrate accurate principal stress and failure location predictions, with stress concentrations primarily observed at the die corners. The results confirm that thermal effects influence stress development more than moisture effects. Finally, a structural sensitivity analysis of the single-package configuration showed that optimizing the thickness of the dies and epoxy molding compound can reduce maximum principal stress by up to 12.4%, providing design insights for improving package-level reliability.

Schlagwörter

Stichwörter der Autor:innen

fan-out panel-level packaginghygrothermal stressmoisture effectreliabilitystructural sensitivity analysis

Autor:innen und Institutionen

  • Department of Mechanical Engineering, National Cheng Kung University, Tainan 70101, Taiwan.
  • Department of Mechanical Engineering, Southern Taiwan University of Science and Technology, Tainan 710301, Taiwan.
  • Packaging Product Simulation and Design Division, Innolux Corporation, Tainan 744092, Taiwan.
  • Testing Center, Innolux Corporation, Tainan 744092, Taiwan.

ORCID-Profile: Cheng-Tse Tsai

Zitieren

APA

Sung, Y. C., Hu, C. P., Hwang, S. J., Shih, M. H., Liao, W. H., Zeng, Y. J., & Tsai, C. T. (2025). Hygrothermal Stress Analysis of Epoxy Molding Compound in Fan-Out Panel-Level Package Based on Experimental Characterization and Structural Sensitivity. Polymers, 17(15), 2034. https://doi.org/10.3390/polym17152034

Vancouver

Sung YC, Hu CP, Hwang SJ, Shih MH, Liao WH, Zeng YJ, et al. Hygrothermal Stress Analysis of Epoxy Molding Compound in Fan-Out Panel-Level Package Based on Experimental Characterization and Structural Sensitivity. Polymers. 2025;17(15):2034. doi:10.3390/polym17152034

BibTeX
@article{Sung2025,
  author = {Sung, Yu-Chi and Hu, Chih-Ping and Hwang, Sheng-Jye and Shih, Ming-Hsien and Liao, Wen-Hsiang and Zeng, Yong-Jie and Tsai, Cheng-Tse},
  title = {Hygrothermal Stress Analysis of Epoxy Molding Compound in Fan-Out Panel-Level Package Based on Experimental Characterization and Structural Sensitivity},
  journal = {Polymers},
  year = {2025},
  volume = {17},
  number = {15},
  pages = {2034},
  doi = {10.3390/polym17152034}
}
Kostenlos starten →