The Effects of Intensity, Exposure Time, and Distance of Polymerization Light on Vickers Microhardness and Temperature Rise of Conventional Resin-Based Composite
Polymers · 14.11.2024 · 16 (22) · 3175
DOI: 10.3390/polym16223175 ↗Kurz gefasst
Fachartikel in der Zeitschrift Polymers, online erschienen am 14.11.2024. Verfasst von Damir Duratbegović und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric and Preventive Dentistry, Faculty of Dentistry with Dental Clinical Center, University of Sarajevo, 71000 Sarajevo, Bosnia an…. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 75 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science, Higher Education and Youth of the Sarajevo Canton, Bosnia and Herzegovina, The Ministry of Science, Higher Education and Youth of the Sarajevo Canton, BiH.
Abstract (Originalsprache)
(1)
Background
This study investigates the effects of curing light intensity, exposure time, and distance on the Vickers microhardness (VMH), hardness bottom-to-top ratio (HR), and temperature rise (TR) of conventional dental resin-based composite (RBC). (2) Materials and Methods: Specimens of one conventional RBC (Tetric EvoCeram, Ivoclar Vivadent) were cured with 12 different curing protocols (CPs), created with three different light intensities (Quartz Tungsten Halogen 300 mW/cm2, LED 650 mW/cm2, LED 1100 mW/cm2), two exposure times (20 and 40 s), and two distances of curing tip (0 and 8 mm). The VMH of top (VMH-T) and bottom (VMH-B) surfaces was measured. The hardness bottom-to-top ratio (HR) was calculated from VMH-B and VMH-T. The HR below 80% was rated as inadequate polymerization. The TR at the depth of 2 mm within the RBC was measured using a K-type thermocouple. Data were analyzed using Levene’s test and the multivariate analysis of variance (MANOVA). The level of significance was set at p < 0.05. (3)
Results
Exposure time and distance significantly influenced VMH-B and HR. Increased distance significantly reduced VMH-B, HR, and TR. CPs 300 mW/cm2/8 mm/20 s and 650 mW/cm2/8 mm/20 s produced inadequate polymerization (HR < 80%). Prolonged exposure time produced higher values of VMH-B and HR. The TR was significantly influenced by light intensity and distance. (4)
Conclusions
Suboptimal light intensity (
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pediatric and Preventive Dentistry, Faculty of Dentistry with Dental Clinical Center, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
- Department of Mechanical Design, Faculty of Mechanical Engineering, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
- Department of Restorative Dentistry and Endodontics, Faculty of Dentistry with Dental Clinical Center, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
ORCID-Profile: Damir Duratbegović, Nedim Pervan
Förderung
- Ministry of Science, Higher Education and Youth of the Sarajevo Canton, Bosnia and Herzegovina
- The Ministry of Science, Higher Education and Youth of the Sarajevo Canton, BiH
Zitieren
APA
Duratbegović, D., Pervan, N., Jakupović, S., & Kobašlija, S. (2024). The Effects of Intensity, Exposure Time, and Distance of Polymerization Light on Vickers Microhardness and Temperature Rise of Conventional Resin-Based Composite. Polymers, 16(22), 3175. https://doi.org/10.3390/polym16223175
Vancouver
Duratbegović D, Pervan N, Jakupović S, Kobašlija S. The Effects of Intensity, Exposure Time, and Distance of Polymerization Light on Vickers Microhardness and Temperature Rise of Conventional Resin-Based Composite. Polymers. 2024;16(22):3175. doi:10.3390/polym16223175
BibTeX
@article{Duratbegovi2024,
author = {Duratbegović, Damir and Pervan, Nedim and Jakupović, Selma and Kobašlija, Sedin},
title = {The Effects of Intensity, Exposure Time, and Distance of Polymerization Light on Vickers Microhardness and Temperature Rise of Conventional Resin-Based Composite},
journal = {Polymers},
year = {2024},
volume = {16},
number = {22},
pages = {3175},
doi = {10.3390/polym16223175}
}