EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optical Design and Analysis of a Conical Scan-Type Slanted Off-Axis Camera

Yiting Wang, Xi He, Zongqiang Fu, Rui Duan, Xiubin Yang

Photonics · 21.04.2026 · 13 (4) · 400

DOI: 10.3390/photonics13040400 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Photonics, online erschienen am 21.04.2026. Verfasst von Yiting Wang und 4 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Jilin Province Science and Technology Department.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Compared with the conventional push-broom imaging mode, conical scanning extends the imaging swath through rotational scanning and is suitable for high-resolution, wide-swath remote sensing. To achieve continuous full-coverage imaging, the camera must be mounted at a certain tilt angle and employ an off-axis optical system with a sufficiently large field of view (FOV). However, the tilted installation causes nonuniform irradiance and increased off-axis distortion, while wide-field off-axis imaging also introduces radiometric consistency problems in focal-plane multi-detector stitching. To address these issues, this study investigates the optical design of a tilted off-axis camera for conical-scan imaging. Under the constraints of full coverage and swath requirements, key optical parameters were jointly determined, and a lightweight wide-coverage off-axis three-mirror system was designed, optimized, and evaluated. The final system has a focal length of 1545 mm, an F-number of 8.4, and a full FOV of 23.4° × 11.7°. The modulation transfer function is greater than 0.41 at the Nyquist frequency, and the maximum distortion is less than 2.5446%. In addition, for the focal-plane optical stitching structure, the coupled effects of local structural vignetting and global geometric vignetting induced by the tilted installation were analyzed. The results show that the gray-level difference in the adjacent detector overlap regions is only 0.31–0.53 digital numbers (DN), and the full focal plane shows a smooth gray-level attenuation rate of 5.39–6.77%. These results indicate that vignetting has no significant effect on focal-plane stitching. The proposed camera is well suited for conical-scan imaging.

Förderung

  • Jilin Province Science and Technology Department

Zitieren

APA

Wang, Y., He, X., Fu, Z., Duan, R., & Yang, X. (2026). Optical Design and Analysis of a Conical Scan-Type Slanted Off-Axis Camera. Photonics, 13(4), 400. https://doi.org/10.3390/photonics13040400

Vancouver

Wang Y, He X, Fu Z, Duan R, Yang X. Optical Design and Analysis of a Conical Scan-Type Slanted Off-Axis Camera. Photonics. 2026;13(4):400. doi:10.3390/photonics13040400

BibTeX
@article{Wang2026,
  author = {Wang, Yiting and He, Xi and Fu, Zongqiang and Duan, Rui and Yang, Xiubin},
  title = {Optical Design and Analysis of a Conical Scan-Type Slanted Off-Axis Camera},
  journal = {Photonics},
  year = {2026},
  volume = {13},
  number = {4},
  pages = {400},
  doi = {10.3390/photonics13040400}
}
Kostenlos starten →