EUVIMEDEUVIMED entdecken
Crossref

Double Zernike polynomial-based desensitization design method for off-axis optical systems

Yan Mo, Hao Tan, Haibo Wang, Zhuang Qian, Donglin Ma

Optics Express · 29.06.2026 · 34 (13) · 23656

DOI: 10.1364/oe.603650 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Express, online erschienen am 17.06.2026. Verfasst von Yan Mo und 4 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key R&D Program of China, Science, Technology and Innovation Commission of Shenzhen Municipality, China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-performance off-axis optical systems require not only excellent nominal performance but also strong robustness against alignment tolerances. However, in conventional desensitization procedures for off-axis systems, the lack of an efficient full-field wavefront representation and sensitivity evaluation framework limits the design efficiency. In this work, a practical desensitization design method is developed by integrating the double Zernike (DZ) polynomial with nodal aberration sensitivity (NAS). The double Zernike expansion is introduced as the full-field representation of the optical path difference (OPD) to address the lack of field dependence in Zernike polynomials. The DZ coefficient matrix is determined through discrete orthogonality and Gaussian quadrature (GQ) with specific sampling conditions in both the field and pupil domains. Based on the DZ coefficient matrix, the full-field wavefront representation is incorporated into an NAS-guided sensitivity evaluation. The full-field wavefront reconstruction capability of DZ polynomials is validated in a TMA (three-mirror anastigmat) system. The DZ-based aberration model is then incorporated into a sensitivity-guided desensitization optimization of an off-axis four-mirror telescope for gravitational-wave detection. Under the same alignment tolerances, the maximum full-field RMS wavefront error of the optimized design at the 90% cumulative probability level is reduced from 0.0843λ to 0.0324λ (λ = 1064 nm). These results demonstrate the effectiveness of the proposed method for full-field wavefront reconstruction and robust design of complex off-axis optical systems.

Förderung

  • National Natural Science Foundation of China
  • National Key R&D Program of China
  • Science, Technology and Innovation Commission of Shenzhen Municipality, China
  • Huazhong University of Science and Technology

Zitieren

APA

Mo, Y., Tan, H., Wang, H., Qian, Z., & Ma, D. (2026). Double Zernike polynomial-based desensitization design method for off-axis optical systems. Optics Express, 34(13), 23656. https://doi.org/10.1364/oe.603650

Vancouver

Mo Y, Tan H, Wang H, Qian Z, Ma D. Double Zernike polynomial-based desensitization design method for off-axis optical systems. Optics Express. 2026;34(13):23656. doi:10.1364/oe.603650

BibTeX
@article{Mo2026,
  author = {Mo, Yan and Tan, Hao and Wang, Haibo and Qian, Zhuang and Ma, Donglin},
  title = {Double Zernike polynomial-based desensitization design method for off-axis optical systems},
  journal = {Optics Express},
  year = {2026},
  volume = {34},
  number = {13},
  pages = {23656},
  doi = {10.1364/oe.603650}
}
Kostenlos starten →