Design of the off-axis neutron camera for the Mega Ampere Spherical Tokamak (MAST) Upgrade
Review of Scientific Instruments · 01.11.2026 · 97 (11)
DOI: 10.1063/5.0350202 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 03.11.2026. Verfasst von RamKrishan Sharma und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, Durham University, Durham DH1 3LE, United Kingdom. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council, Vetenskapsrådet.
Abstract (Originalsprache)
A dedicated four-channel, collimated neutron flux monitor has been designed for the Mega Ampere Spherical Tokamak (MAST) Upgrade to measure spatially resolved neutron emissivity in the off-axis Neutral Beam Injection (NBI) region, contributing to studies of fast-ion confinement and the effectiveness of plasma heating and current drive. This paper presents the design and motivation for the off-axis neutron camera (OANC) for MAST Upgrade. It describes the line-of-sight geometry, detection system, shielding configuration, and laboratory characterization of detectors using γ-ray sources. The OANC is optimized to complement the existing on-axis Neutron Camera Upgrade diagnostics and provide measurements in previously inaccessible regions. The design achieves 10% statistical accuracy with 10 ms time resolution in off-axis NBI scenarios. The diagnostic will be installed during the next engineering break and will become operational in the following campaign. The off-axis neutron camera is expected to provide valuable insights into fast-ion deposition, plasma heating, and confinement driven by off-axis NBI.
Autor:innen und Institutionen
- Department of Physics, Durham University, Durham DH1 3LE, United Kingdom.
- Department of Physics and Astronomy, Uppsala University, Uppsala SE-751 05, Sweden.
- UKAEA, Culham Campus, Abingdon, Oxfordshire, OX14 3DB, United Kingdom.
ORCID-Profile: RamKrishan Sharma, Marco Cecconello
Förderung
- Engineering and Physical Sciences Research Council
- Vetenskapsrådet
Zitieren
APA
Sharma, R., Cecconello, M., & Fitzgerald, I. (2026). Design of the off-axis neutron camera for the Mega Ampere Spherical Tokamak (MAST) Upgrade. Review of Scientific Instruments, 97(11). https://doi.org/10.1063/5.0350202
Vancouver
Sharma R, Cecconello M, Fitzgerald I. Design of the off-axis neutron camera for the Mega Ampere Spherical Tokamak (MAST) Upgrade. Review of Scientific Instruments. 2026;97(11). doi:10.1063/5.0350202
BibTeX
@article{Sharma2026,
author = {Sharma, RamKrishan and Cecconello, Marco and Fitzgerald, Ian},
title = {Design of the off-axis neutron camera for the Mega Ampere Spherical Tokamak (MAST) Upgrade},
journal = {Review of Scientific Instruments},
year = {2026},
volume = {97},
number = {11},
doi = {10.1063/5.0350202}
}
EUVIMED