EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Volumetric Wear and Aligner Retention of Composite Resins for Orthodontic Attachments: A Micro-CT-Based In Vitro Assessment

Sandra Maria Mesquita Alves Uchôa, Dimorvan Bordin, Murilo Matias, José Augusto Rodrigues, Hélio Doyle Pereira da Silva, Pedro Cesar Gomes Titato, Marco Antonio Hungaro Duarte, Liliana Ávila Maltagliati

Oral · 15.07.2026 · 6 (4) · 90

DOI: 10.3390/oral6040090 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Oral, online erschienen am 15.07.2026. Verfasst von Sandra Maria Mesquita Alves Uchôa und 7 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Composite attachments play a key role in clear aligner biomechanics; however, their structural stability and wear behavior under repetitive insertion–removal cycles remain poorly understood. Limited evidence exists regarding how composite resins degrade volumetrically and whether such changes influence aligner retention during simulated clinical use. This study evaluated the performance of three commonly used composites for orthodontic attachments.

Methods

Digital hemi-arch models were 3D printed and attachments were fabricated using two low-viscosity composites (Transbond™ Supreme LV and Filtek™ Bulk Fill Flow) and one high-viscosity composite (Filtek™ Z250XT). Baseline attachment volumes were assessed using micro-computed tomography (microCT). Nine aligners per model were fabricated to simulate three months of treatment, with each aligner subjected to 30 insertion–removal cycles (270 cycles/model). The maximum tensile force required for aligner detachment was recorded for every cycle. Following mechanical testing, attachments underwent post-test microCT scanning. Intragroup volumetric changes were analyzed using paired t-tests; intergroup differences were assessed with ANOVA, followed by ANCOVA. Tensile-force patterns were evaluated using repeated-measures ANOVA.

Results

Significant volumetric loss occurred for Transbond™ Supreme LV and Filtek™ Z250XT, whereas Filtek™ Bulk Fill Flow exhibited minimal wear. Nonetheless, intergroup volumetric differences were not statistically significant. Tensile forces were statistically different between groups for most measurements, yet within each set of 30 cycles, they exhibited a similar pattern of progressively decreasing force.

Conclusions

During the simulated three-month period, all three composite resins exhibited some degree of volumetric wear and a progressive decrease in aligner detachment force within each set of cycles. The Filtek™ Bulk Fill Flow exhibited numerically higher and more consistent forces and minimal surface wear; however, no statistically significant differences were observed in total volumetric loss among groups, and the observed variations in tensile forces did not appear to compromise the overall performance of attachments, suggesting that all tested resins maintained clinically relevant retention under the conditions of this study.

Zitieren

APA

Uchôa, S. M. M. A., Bordin, D., Matias, M., Rodrigues, J. A., Silva, H. D. P. D., Titato, P. C. G., Duarte, M. A. H., & Maltagliati, L. Á. (2026). Volumetric Wear and Aligner Retention of Composite Resins for Orthodontic Attachments: A Micro-CT-Based In Vitro Assessment. Oral, 6(4), 90. https://doi.org/10.3390/oral6040090

Vancouver

Uchôa SMMA, Bordin D, Matias M, Rodrigues JA, Silva HDPD, Titato PCG, et al. Volumetric Wear and Aligner Retention of Composite Resins for Orthodontic Attachments: A Micro-CT-Based In Vitro Assessment. Oral. 2026;6(4):90. doi:10.3390/oral6040090

BibTeX
@article{Ucha2026,
  author = {Uchôa, Sandra Maria Mesquita Alves and Bordin, Dimorvan and Matias, Murilo and Rodrigues, José Augusto and Silva, Hélio Doyle Pereira da and Titato, Pedro Cesar Gomes and Duarte, Marco Antonio Hungaro and Maltagliati, Liliana Ávila},
  title = {Volumetric Wear and Aligner Retention of Composite Resins for Orthodontic Attachments: A Micro-CT-Based In Vitro Assessment},
  journal = {Oral},
  year = {2026},
  volume = {6},
  number = {4},
  pages = {90},
  doi = {10.3390/oral6040090}
}
Kostenlos starten →