Effect of print orientation of 3D-printed aligner templates on the volumetric accuracy of transferred composite attachments: an in vitro study
Clinical Oral Investigations · 26.12.2025 · 30 (1)
DOI: 10.1007/s00784-025-06708-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oral Investigations, online erschienen am 26.12.2025. Verfasst von Samuele Avolese und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Aerospace Engineering, Polytechnic University of Turin, Torino, Italy. samuele.avolese@polito.it. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Tooth Movement Techniques, Orthodontic Appliance Design, Composite Resins. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES: This study aimed to evaluate the effect of print orientation on the dimensional accuracy of attachments in directly 3D-printed orthodontic aligners. MATERIALS AND METHODS: For n = 10 patients, 34 single-tooth aligner segments were digitally designed (17 for tooth 1.1 and 17 for tooth 1.6) incorporating a planned 3 mm horizontal rectangular buccal attachment. These aligners were printed in TC-85 DAC resin (Graphy Inc, Seoul, Korea) at different inclinations (8 in anterotation and 8 in postrotation, at 10° intervals from the horizontal) and used as templates to transfer attachments onto corresponding 3D-printed dental models. This models with transferred attachments were scanned with a laboratory scanner and superimposed onto the attachment surface of the master digital file. Percentage volume deviations of the transferred versus planned attachment were quantified using Geomagic Control software (v.2020.1.1, ©2020 3D Systems, Inc., Rock Hill, SC) and analysed with an unpaired two-tailed t-test (P < 0.05). RESULTS: For tooth 1.1, the mean volumetric deviation of transferred attachments was significantly lower in postrotation orientations (88.87% ± 4.13) than in anterotation (69.01% ± 4.33), indicating that positioning the template with the vestibular surface facing the build platform improves accuracy (p < 0.0001). For tooth 1.6, no statistically significant difference was found (p = 0.0992; 78.16% ± 2.26 vs. 79.99% ± 1.87). CONCLUSIONS: Composite attachments transferred with 3D-printed templates exhibited a volumetric alteration respect the master digital file and print orientation particularly affects anterior teeth's attachments. CLINICAL RELEVANCE: Aligners orientation during 3D-printing is crucial to ensure accurate attachments transfer, especially anterior regions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Mechanical and Aerospace Engineering, Polytechnic University of Turin, Torino, Italy. samuele.avolese@polito.it.
- Specialization School in Orthodontics, Department of Surgical Sciences, Dental School of the University of Torino, Torino, Italy. samuele.avolese@polito.it.
- Specialization School in Orthodontics, Department of Surgical Sciences, Dental School of the University of Torino, Torino, Italy.
- Polito BIO Med Lab, Polytechnic University of Turin, Torino, Italy.
- Department of Mechanical and Aerospace Engineering, Polytechnic University of Turin, Torino, Italy.
- Department of Surgical Sciences, Dental School, University of Torino, Torino, Italy.
Zitieren
APA
Avolese, S., Parrini, S., Lava, D., Lugas, A. T., Bignardi, C., Terzini, M., Muraca, D., Scotti, N., & Sanna, F. (2025). Effect of print orientation of 3D-printed aligner templates on the volumetric accuracy of transferred composite attachments: an in vitro study. Clinical Oral Investigations, 30(1). https://doi.org/10.1007/s00784-025-06708-4
Vancouver
Avolese S, Parrini S, Lava D, Lugas AT, Bignardi C, Terzini M, et al. Effect of print orientation of 3D-printed aligner templates on the volumetric accuracy of transferred composite attachments: an in vitro study. Clinical Oral Investigations. 2025;30(1). doi:10.1007/s00784-025-06708-4
BibTeX
@article{Avolese2025,
author = {Avolese, Samuele and Parrini, Simone and Lava, Danila and Lugas, Andrea Tancredi and Bignardi, Cristina and Terzini, Mara and Muraca, Danila and Scotti, Nicola and Sanna, Fabrizio},
title = {Effect of print orientation of 3D-printed aligner templates on the volumetric accuracy of transferred composite attachments: an in vitro study},
journal = {Clinical Oral Investigations},
year = {2025},
volume = {30},
number = {1},
doi = {10.1007/s00784-025-06708-4}
}
EUVIMED