EUVIMEDEUVIMED entdecken
Crossref

Effect of print orientation of 3D-printed aligner templates on the volumetric accuracy of transferred composite attachments: an in vitro study

Samuele Avolese, Simone Parrini, Danila Lava, Andrea Tancredi Lugas, Cristina Bignardi, Mara Terzini, Danila Muraca, Nicola Scotti, Fabrizio Sanna

Clinical Oral Investigations · 26.12.2025 · 30 (1)

DOI: 10.1007/s00784-025-06708-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Investigations, online erschienen am 26.12.2025. Verfasst von Samuele Avolese und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Aerospace Engineering, Polytechnic University of Turin, Torino, Italy. samuele.avolese@polito.it. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Tooth Movement Techniques, Orthodontic Appliance Design, Composite Resins. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: This study aimed to evaluate the effect of print orientation on the dimensional accuracy of attachments in directly 3D-printed orthodontic aligners. MATERIALS AND METHODS: For n = 10 patients, 34 single-tooth aligner segments were digitally designed (17 for tooth 1.1 and 17 for tooth 1.6) incorporating a planned 3 mm horizontal rectangular buccal attachment. These aligners were printed in TC-85 DAC resin (Graphy Inc, Seoul, Korea) at different inclinations (8 in anterotation and 8 in postrotation, at 10° intervals from the horizontal) and used as templates to transfer attachments onto corresponding 3D-printed dental models. This models with transferred attachments were scanned with a laboratory scanner and superimposed onto the attachment surface of the master digital file. Percentage volume deviations of the transferred versus planned attachment were quantified using Geomagic Control software (v.2020.1.1, ©2020 3D Systems, Inc., Rock Hill, SC) and analysed with an unpaired two-tailed t-test (P < 0.05). RESULTS: For tooth 1.1, the mean volumetric deviation of transferred attachments was significantly lower in postrotation orientations (88.87% ± 4.13) than in anterotation (69.01% ± 4.33), indicating that positioning the template with the vestibular surface facing the build platform improves accuracy (p < 0.0001). For tooth 1.6, no statistically significant difference was found (p = 0.0992; 78.16% ± 2.26 vs. 79.99% ± 1.87). CONCLUSIONS: Composite attachments transferred with 3D-printed templates exhibited a volumetric alteration respect the master digital file and print orientation particularly affects anterior teeth's attachments. CLINICAL RELEVANCE: Aligners orientation during 3D-printing is crucial to ensure accurate attachments transfer, especially anterior regions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalTooth Movement TechniquesOrthodontic Appliance DesignComposite ResinsHumansModels, DentalIn Vitro TechniquesComputer-Aided Design

Stichwörter der Autor:innen

3-dimensional printingAttachmentClear aligner therapyPrint orientation

Substanzen

Composite Resins

Autor:innen und Institutionen

  • Department of Mechanical and Aerospace Engineering, Polytechnic University of Turin, Torino, Italy. samuele.avolese@polito.it.
  • Specialization School in Orthodontics, Department of Surgical Sciences, Dental School of the University of Torino, Torino, Italy. samuele.avolese@polito.it.
  • Specialization School in Orthodontics, Department of Surgical Sciences, Dental School of the University of Torino, Torino, Italy.
  • Polito BIO Med Lab, Polytechnic University of Turin, Torino, Italy.
  • Department of Mechanical and Aerospace Engineering, Polytechnic University of Turin, Torino, Italy.
  • Department of Surgical Sciences, Dental School, University of Torino, Torino, Italy.

Zitieren

APA

Avolese, S., Parrini, S., Lava, D., Lugas, A. T., Bignardi, C., Terzini, M., Muraca, D., Scotti, N., & Sanna, F. (2025). Effect of print orientation of 3D-printed aligner templates on the volumetric accuracy of transferred composite attachments: an in vitro study. Clinical Oral Investigations, 30(1). https://doi.org/10.1007/s00784-025-06708-4

Vancouver

Avolese S, Parrini S, Lava D, Lugas AT, Bignardi C, Terzini M, et al. Effect of print orientation of 3D-printed aligner templates on the volumetric accuracy of transferred composite attachments: an in vitro study. Clinical Oral Investigations. 2025;30(1). doi:10.1007/s00784-025-06708-4

BibTeX
@article{Avolese2025,
  author = {Avolese, Samuele and Parrini, Simone and Lava, Danila and Lugas, Andrea Tancredi and Bignardi, Cristina and Terzini, Mara and Muraca, Danila and Scotti, Nicola and Sanna, Fabrizio},
  title = {Effect of print orientation of 3D-printed aligner templates on the volumetric accuracy of transferred composite attachments: an in vitro study},
  journal = {Clinical Oral Investigations},
  year = {2025},
  volume = {30},
  number = {1},
  doi = {10.1007/s00784-025-06708-4}
}
Kostenlos starten →