Micro-computed tomography evaluation of aligner fitting on anchorage attachments
Korean Journal of Orthodontics · 25.07.2026 · 56 (4) · 316-326
DOI: 10.4041/kjod25.170 ↗Kurz gefasst
Fachartikel in der Zeitschrift Korean Journal of Orthodontics, online erschienen am 25.02.2026. Verfasst von İlter Burak Köse und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Mersin Oral and Dental Health Hospital, Mersin, Türkiye. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objective
To evaluate the fit of clear aligners (CAs) manufactured from different materials and thicknesses to anchorage attachments using micro-computed tomography-based (Micro-CT) three-dimensional and two-dimensional analyses.
Methods
Forty CAs fabricated from different thicknesses and materials (0.50 mm CA-Soft, 0.625 mm CA-Medium, 0.75 mm CA-Hard polyethylene terephthalate glycol [PET-G], and 0.75 mm CA PRO-Hard ABA) were fitted onto a master model with rectangular attachments on the first and second premolars. Micro-CT scans were obtained to assess the air gap between the aligner and attachment. Total air-gap volume was calculated using three-dimensional volumetric analysis, while mean gap width was measured in predefined two-dimensional sections. Adjusted mean differences were interpreted using a practical relevance threshold of 20 μm. Results: = 0.054), buccal, frontomedian, mesial, or occlusal sections.
Conclusions
Micro-CT enabled detailed assessment of CA fit. Although volumetric analysis showed no significant material-related differences, section-based analysis demonstrated localized adaptation differences, particularly in palatal, gingival, and sagittomedian regions. CA PRO-Hard showed superior fit in these areas.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthodontics, Mersin Oral and Dental Health Hospital, Mersin, Türkiye.
- Department of Orthodontics, Hatay Mustafa Kemal University, Hatay, Türkiye.
- Department of Prosthodontics, Akdeniz University, Antalya, Türkiye.
ORCID-Profile: İlter Burak Köse, Eyüp Burak Küçük, Meral Arslan Malkoç
Zitieren
APA
Köse, İ. B., Küçük, E. B., & Malkoç, M. A. (2026). Micro-computed tomography evaluation of aligner fitting on anchorage attachments. Korean Journal of Orthodontics, 56(4), 316-326. https://doi.org/10.4041/kjod25.170
Vancouver
Köse İB, Küçük EB, Malkoç MA. Micro-computed tomography evaluation of aligner fitting on anchorage attachments. Korean Journal of Orthodontics. 2026;56(4):316-326. doi:10.4041/kjod25.170
BibTeX
@article{Kse2026,
author = {Köse, İlter Burak and Küçük, Eyüp Burak and Malkoç, Meral Arslan},
title = {Micro-computed tomography evaluation of aligner fitting on anchorage attachments},
journal = {Korean Journal of Orthodontics},
year = {2026},
volume = {56},
number = {4},
pages = {316--326},
doi = {10.4041/kjod25.170}
}