EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Electrochemiluminescence/Electrochemistry Dual-Mode Synchronous Sensing of Pb2+ Based on G4–hemin DNAzyme Complex During One-Step Scan

Rukai Wei, Lei Shang iD, Wei Zhang iD, Xiaojian Li, Liping Jia, Rongna Ma, Huaisheng Wang

Molecules · 2025

DOI: 10.3390/molecules30091951 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, 2025. Verfasst von Rukai Wei und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Liaocheng University, Liaocheng 252059, China. Hauptthemen laut MEDLINE: DNA, Catalytic, Lead, G-Quadruplexes, Hemin. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Shandong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrochemiluminescence (ECL)/electrochemistry (EC) dual-mode sensors have garnered significant interest for their enhanced analytical reliability through the cross-verification of dual-signal outputs. However, conventional approaches necessitate two potential scans to acquire ECL and EC signals independently, resulting in temporal and environmental discrepancies between the two detection modes. In this paper, we present a novel synchronous ECL/EC dual-mode sensing platform for lead ion (Pb2+) detection via a one-step potential scan (0.2 to −0.4 V vs. Ag/AgCl) utilizing a G-quadruplex (G4)–hemin DNAzyme complex. This complex synergistically catalyzed the electrochemical reduction of dissolved oxygen, concurrently generating a distinct cathodic ECL emission from Ru(bpy)32+ and a synchronous reduction current peak at −0.25 V. Pb2+ quantification was achieved through its dose-dependent suppression of DNAzyme activity by destabilizing the G4–hemin interaction, thereby proportionally attenuating both ECL intensity and EC signal (reduction current). The integrated sensor demonstrated high sensitivity (detection limits of 1.51 nM for ECL detection and 2.03 nM for EC detection), robust anti-interference capability, and satisfactory reproducibility, with recoveries ranging from 95.5 to 103.1% in environmental water analysis. This work established a paradigm for one-step dual-mode sensor design, offering new prospects for environmental monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DNA, CatalyticLeadG-QuadruplexesHeminBiosensing TechniquesElectrochemical TechniquesLuminescent MeasurementsLimit of DetectionWater Pollutants, Chemical

Stichwörter der Autor:innen

ECL/ECG4–heminPb2+dual modeone-step scan

Substanzen

DNA, CatalyticLeadHeminWater Pollutants, Chemical

Autor:innen und Institutionen

  • Department of Chemistry, Liaocheng University, Liaocheng 252059, China.

ORCID-Profile: Lei Shang, Wei Zhang

Förderung

  • Natural Science Foundation of Shandong Province

Zitieren

APA

Wei, R., Shang, L., Zhang, W., Li, X., Jia, L., Ma, R., & Wang, H. (2025). Electrochemiluminescence/Electrochemistry Dual-Mode Synchronous Sensing of Pb2+ Based on G4–hemin DNAzyme Complex During One-Step Scan. Molecules. https://doi.org/10.3390/molecules30091951

Vancouver

Wei R, Shang L, Zhang W, Li X, Jia L, Ma R, et al. Electrochemiluminescence/Electrochemistry Dual-Mode Synchronous Sensing of Pb2+ Based on G4–hemin DNAzyme Complex During One-Step Scan. Molecules. 2025. doi:10.3390/molecules30091951

BibTeX
@article{Wei2025,
  author = {Wei, Rukai and Shang, Lei and Zhang, Wei and Li, Xiaojian and Jia, Liping and Ma, Rongna and Wang, Huaisheng},
  title = {Electrochemiluminescence/Electrochemistry Dual-Mode Synchronous Sensing of Pb2+ Based on G4–hemin DNAzyme Complex During One-Step Scan},
  journal = {Molecules},
  year = {2025},
  doi = {10.3390/molecules30091951}
}
Kostenlos starten →