High fidelity detection of miRNAs from complex physiological samples through electrochemical nanosensors empowered by proximity catalysis and magnetic separation

Shuqi Tang, Xiyue Xie, Lin Li, Luoli Zhou, Yuxin Xing, Yuhua Chen, Kaiyong Cai, Fan Li, Jixi Zhang

Biosensors and Bioelectronics · 2024-09 · 260 · 116435

DOI: 10.1016/j.bios.2024.116435 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-09. Verfasst von Shuqi Tang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, No. 174 Shazheng Roa…. Hauptthemen laut MEDLINE: Biosensing Techniques, MicroRNAs, Electrochemical Techniques, DNA, Catalytic. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: Graduate Scientific Research and Innovation Foundation of Chongqing, Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrochemical detection of miRNA biomarkers in complex physiological samples holds great promise for accurate evaluation of tumor burden in the perioperative period, yet limited by reproducibility and bias issues. Here, nanosensors installed with hybrid probes that responsively release catalytic DNAzymes (G-quadruplexes/hemin) were developed to solve the fidelity challenge in an immobilization-free detection. miRNA targets triggered toehold-mediated strand displacement reactions on the sensor surface and resulted in amplified shedding of DNAzymes. Subsequently, the interference background was removed by Fe3O4 core-facilitated magnetic separation. Binding aptamers of the electrochemical reporter (dopamine) were tethered closely to the catalytic units for boosting H2O2-mediated oxidation through proximity catalysis. The one-to-many conversion by dual amplification from biological-chemical catalysis facilitated sufficient homogeneous sensing signals on electrodes. Thereby, the nanosensor exhibited a low detection limit (2.08 fM), and high reproducibility (relative standard deviation of 1.99%). Most importantly, smaller variations (RSD of 0.51-1.04%) of quantified miRNAs were observed for detection from cell lysates, multiplexed detection from unprocessed serum, and successful discrimination of small upregulations in lysates of tumor tissue samples. The nanosensor showed superior diagnostic performance with an area under curve (AUC) of 0.97 and 94% accuracy in classifying breast cancer patients and healthy donors. These findings demonstrated the synergy of signal amplification and interference removal in achieving high-fidelity miRNA detection for practical clinical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesMicroRNAsElectrochemical TechniquesDNA, CatalyticLimit of DetectionHumansCatalysisG-QuadruplexesBreast NeoplasmsHydrogen PeroxideAptamers, NucleotideFemaleHeminReproducibility of ResultsBiomarkers, Tumor

Stichwörter der Autor:innen

Electrochemical detectionInterference removalNanosensorProximity catalysisSignal amplificationTumor markers

Substanzen

MicroRNAsDNA, CatalyticHydrogen PeroxideAptamers, NucleotideHeminBiomarkers, Tumor

Autor:innen und Institutionen

  • Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, No. 174 Shazheng Road, Chongqing, 400044, China.
  • Department of Breast and Thyroid Surgery, The First Affiliated Hospital of Chongqing Medical University, Chongqing, No.1 Youyi Road, Yuzhong District, Chongqing, 400016, China. Electronic address: lf628@163.com.
  • Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, No. 174 Shazheng Road, Chongqing, 400044, China. Electronic address: jixizhang@cqu.edu.cn.

Förderung

  • Graduate Scientific Research and Innovation Foundation of Chongqing
  • Fundamental Research Funds for the Central Universities
  • National Natural Science Foundation of China
  • Natural Science Foundation of Chongqing Municipality
  • Chongqing University
  • Natural Science Foundation Project of Chongqing

Zitieren

APA

Tang, S., Xie, X., Li, L., Zhou, L., Xing, Y., Chen, Y., Cai, K., Li, F., & Zhang, J. (2024). High fidelity detection of miRNAs from complex physiological samples through electrochemical nanosensors empowered by proximity catalysis and magnetic separation. Biosensors and Bioelectronics, 260, 116435. https://doi.org/10.1016/j.bios.2024.116435

Vancouver

Tang S, Xie X, Li L, Zhou L, Xing Y, Chen Y, et al. High fidelity detection of miRNAs from complex physiological samples through electrochemical nanosensors empowered by proximity catalysis and magnetic separation. Biosensors and Bioelectronics. 2024;260:116435. doi:10.1016/j.bios.2024.116435

BibTeX
@article{Tang2024,
  author = {Tang, Shuqi and Xie, Xiyue and Li, Lin and Zhou, Luoli and Xing, Yuxin and Chen, Yuhua and Cai, Kaiyong and Li, Fan and Zhang, Jixi},
  title = {High fidelity detection of miRNAs from complex physiological samples through electrochemical nanosensors empowered by proximity catalysis and magnetic separation},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {260},
  pages = {116435},
  doi = {10.1016/j.bios.2024.116435}
}
Kostenlos starten →