EUVIMEDEUVIMED entdecken
Crossref

An OR-logic-gated polarity-switching biosensor for multiplexed dual-mode thalassemia screening

Yiwei Zheng, Na Feng, Wenwen Xiao, Ruxia Wei, Wenjie Lu, Xu Li, Xuecai Tan, Yashu Wei, Kejing Huang, Jiawen Wu

Biosensors and Bioelectronics · 2027-01 · 316 · 119322

DOI: 10.1016/j.bios.2026.119322 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2027-01. Verfasst von Yiwei Zheng und 9 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Optic-electric Chemo/Biosensing and Molecular Recognition (Guangxi Minzu University), Education Department of Guangxi Zhuang Autono…. Hauptthemen laut MEDLINE: Biosensing Techniques, Thalassemia. Die Arbeit nennt 39 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Guangxi Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The concurrent detection of multiple thalassemia mutations remains challenging due to the limitations of conventional single-readout biosensors in terms of reliability and sensitivity. Herein, we report an intelligent photoelectrochemical (PEC)/colorimetric dual-mode biosensor that integrates an OR logic gate with a DNAzyme Walker cascade amplification strategy, built on a proposed Z-scheme Bi2S3/Bi-BiOI heterojunction whose proposed Z-scheme charge-transfer pathway is supported by Mott-Schottky and photovoltage measurements. The OR logic gate enables parallel recognition of CD142 and CD41-42 mutations, outputting a unified trigger to initiate a nicking enzyme-assisted DNAzyme Walker. This autonomous machinery releases abundant G-quadruplex/hemin (G4-hemin) complexes, serving as a bifunctional signal transducer. Notably, the specific binding of G4-hemin to the electrode interface induces a distinct anodic-to-cathodic photocurrent polarity switching, which, coupled with its intrinsic peroxidase-mimicking activity, allows for self-validated dual-signal output. The platform achieves limits of detection down to 28.7 aM (PEC) and 2.6 fM (colorimetric) across a wide linear range (0.1 fM-0.1 μM). Furthermore, the dual-mode design effectively eliminates false positives through signal cross-validation. Practical application in human serum yielded satisfactory recoveries (94.1-107.8%), highlighting the platform's potential for high-precision genetic screening in resource-limited settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesThalassemiaHumansG-QuadruplexesDNA, CatalyticHeminColorimetryElectrochemical TechniquesEquipment DesignLimit of Detection

Stichwörter der Autor:innen

DNAzyme walkerG-quadruplex/heminOR logic gatePhotocurrent polarity switchingThalassemia screeningZ-Scheme heterojunction

Substanzen

DNA, CatalyticHemin

Autor:innen und Institutionen

  • Key Laboratory of Optic-electric Chemo/Biosensing and Molecular Recognition (Guangxi Minzu University), Education Department of Guangxi Zhuang Autonomous Region; Guangxi Key Laboratory of Chemistry and Engineering of Fo…
  • The Reproductive Hospital of Guangxi Zhuang Autonomous Region, Nanning, 530021, China. Electronic address: 406561460@qq.com.

Förderung

  • National Natural Science Foundation of China
  • Guangxi Natural Science Foundation

Zitieren

APA

Zheng, Y., Feng, N., Xiao, W., Wei, R., Lu, W., Li, X., Tan, X., Wei, Y., Huang, K., & Wu, J. (2027). An OR-logic-gated polarity-switching biosensor for multiplexed dual-mode thalassemia screening. Biosensors and Bioelectronics, 316, 119322. https://doi.org/10.1016/j.bios.2026.119322

Vancouver

Zheng Y, Feng N, Xiao W, Wei R, Lu W, Li X, et al. An OR-logic-gated polarity-switching biosensor for multiplexed dual-mode thalassemia screening. Biosensors and Bioelectronics. 2027;316:119322. doi:10.1016/j.bios.2026.119322

BibTeX
@article{Zheng2027,
  author = {Zheng, Yiwei and Feng, Na and Xiao, Wenwen and Wei, Ruxia and Lu, Wenjie and Li, Xu and Tan, Xuecai and Wei, Yashu and Huang, Kejing and Wu, Jiawen},
  title = {An OR-logic-gated polarity-switching biosensor for multiplexed dual-mode thalassemia screening},
  journal = {Biosensors and Bioelectronics},
  year = {2027},
  volume = {316},
  pages = {119322},
  doi = {10.1016/j.bios.2026.119322}
}
Kostenlos starten →