3D-Printed Closed-Channel Spiral Inertial Microfluidic Device for Size-Based Particle Separation
Micromachines · 31.03.2026 · 17 (4) · 435
DOI: 10.3390/mi17040435 ↗Kurz gefasst
Fachartikel in der Zeitschrift Micromachines, online erschienen am 31.03.2026. Verfasst von Eda Ozyilmaz und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Gebze Technical University, Kocaeli 41400, Türkiye. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Scientific and Technological Research Council of Türkiye (TÜBİTAK).
Abstract (Originalsprache)
Spiral inertial microfluidic devices provide a simple, high-throughput approach for size-based particle separation; however, translating PDMS-optimized designs into monolithic, fully enclosed 3D-printed channels is often limited by printability and post-print channel clearing. In our previous PDMS study, a 400×120µm spiral achieved high separation performance after computational optimization and experimental validation. To translate this high-performing PDMS concept into a faster and more cost-effective manufacturing approach, the same separation principle is transferred to a fully 3D-printed, closed-channel spiral device, and the geometry is re-optimized around manufacturability constraints. Printing trials showed that enclosed channels at 400×120µm and 600×180µm could not be cleared reliably due to trapped resin and frequent blockage, most often near the inner-outlet region. In contrast, 800×240µm and 1200×360µm channels were printed and flushed successfully, and 800×240µm was selected as the smallest reproducibly functional cross-section. Particle-tracking simulations were then used to re-optimize spiral development length, showing that a 4-turn device provides limited collection for 12µm targets (10%), intermediate lengths (5–7 turns) improve collection to 50%, and an 8-turn spiral achieves complete large-particle collection (100%) across tested target sizes (12–24µm) while reducing small-particle crossover. Experimental validation of the 8-turn 800×240µm device at Q=6mL min−1 using fluorescent polystyrene particles (18µm target; 6µm background) yielded an average collection efficiency of 84% and an inner-outlet purity of 92%. Overall, these results demonstrate that spiral inertial separation can be retained in a monolithic 3D-printed format when the design is re-optimized around the smallest reliably clearable enclosed cross-section and sufficient spiral development length.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, Gebze Technical University, Kocaeli 41400, Türkiye.
- Institute for NanoSystems Innovation (NanoSI), Northeastern University, Boston, MA 02115, USA.
ORCID-Profile: Eda Ozyilmaz, Gamze Gediz Ilis
Förderung
- Scientific and Technological Research Council of Türkiye (TÜBİTAK)
Zitieren
APA
Ozyilmaz, E., & Gediz Ilis, G. (2026). 3D-Printed Closed-Channel Spiral Inertial Microfluidic Device for Size-Based Particle Separation. Micromachines, 17(4), 435. https://doi.org/10.3390/mi17040435
Vancouver
Ozyilmaz E, Gediz Ilis G. 3D-Printed Closed-Channel Spiral Inertial Microfluidic Device for Size-Based Particle Separation. Micromachines. 2026;17(4):435. doi:10.3390/mi17040435
BibTeX
@article{Ozyilmaz2026,
author = {Ozyilmaz, Eda and Gediz Ilis, Gamze},
title = {3D-Printed Closed-Channel Spiral Inertial Microfluidic Device for Size-Based Particle Separation},
journal = {Micromachines},
year = {2026},
volume = {17},
number = {4},
pages = {435},
doi = {10.3390/mi17040435}
}