Radioactive isotope separation with 3D-printed flow-based device
Analytical Sciences · 2023-05 · 39 (5) · 671-677
DOI: 10.1007/s44211-022-00254-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Sciences, online erschienen am 13.01.2023. Verfasst von Syohei Obata und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Kumamoto University, 2-39-1 Kurokami, Kumamoto, 860-8555, Japan. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science London.
Abstract (Originalsprache)
Radioactive isotope (RI) metals are a new type of tracer for positron emission tomography generated from the target metal by proton irradiation using a cyclotron. The generated metal RIs need to be separated from the target metal rapidly and effectively. In the present study, we developed a 3D-printed flow device to separate metal RIs from target metals. The separation was performed with selective formation of ethylenediaminetetraacetic acid (EDTA) complex based on the difference in formation constants. The RI metal selectively formed a EDTA complex, thus changing its ionic charge in solution. The solution was then introduced into a cation exchange column for selective adsorption of the target metal. The solution with added chelator and controlled pH was introduced into the developed system and automatically separated metal RI from target metals within 14 min. The separation method was applied to separate RI 67Ga from target metal Zn using a mixture of 107 pg L-1 67Ga in 250 mg L-1 Zn2+. The recoveries of 67Ga and Zn were 97% and 100%, respectively. Furthermore, an ultraviolet (UV) radiation reactor was integrated into the system to decompose the EDTA complex and recover the Ga3+ ion. Ga3+ recovery by UV radiation was effective, 87%. The developed system was also successfully applied to the separation of Zr and Y. Therefore, the method and system can be applied to separate other metal RIs from target metals.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemistry, Kumamoto University, 2-39-1 Kurokami, Kumamoto, 860-8555, Japan.
- Department of Radiation-Applied Biology Research, Takasaki Advanced Radiation Research Institute, National Institutes for Quantum Science and Technology, 1233 Watanuki, Takasaki, 370-1292, Japan. sugo.yumi@qst.go.jp.
- Faculty of Science and Technology, Kochi University, 2-5-1 Akebono-Cho, Kochi, 780-8520, Japan.
- Department of Radiation-Applied Biology Research, Takasaki Advanced Radiation Research Institute, National Institutes for Quantum Science and Technology, 1233 Watanuki, Takasaki, 370-1292, Japan.
- Faculty of Science and Technology, Kochi University, 2-5-1 Akebono-Cho, Kochi, 780-8520, Japan. mori@kochi-u.ac.jp.
- Department of Chemistry, Kumamoto University, 2-39-1 Kurokami, Kumamoto, 860-8555, Japan. ohira@kumamoto-u.ac.jp.
Förderung
- Japan Society for the Promotion of Science London
Zitieren
APA
Obata, S., Sugo, Y., Manabe, H., Arima, Y., Toda, K., Ishioka, N. S., Mori, M., & Ohira, S. I. (2023). Radioactive isotope separation with 3D-printed flow-based device. Analytical Sciences, 39(5), 671-677. https://doi.org/10.1007/s44211-022-00254-9
Vancouver
Obata S, Sugo Y, Manabe H, Arima Y, Toda K, Ishioka NS, et al. Radioactive isotope separation with 3D-printed flow-based device. Analytical Sciences. 2023;39(5):671-677. doi:10.1007/s44211-022-00254-9
BibTeX
@article{Obata2023,
author = {Obata, Syohei and Sugo, Yumi and Manabe, Hinako and Arima, Yuto and Toda, Kei and Ishioka, Noriko S and Mori, Masanobu and Ohira, Shin-Ichi},
title = {Radioactive isotope separation with 3D-printed flow-based device},
journal = {Analytical Sciences},
year = {2023},
volume = {39},
number = {5},
pages = {671--677},
doi = {10.1007/s44211-022-00254-9}
}
EUVIMED