Biomechanical Comparison of Three Different Fixation Methods for Unstable Basicervical Intertrochanteric Fractures Using a Novel Cephalomedullary Nail
Medicina · 2026
DOI: 10.3390/medicina62020322 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Medicina, 2026. Verfasst von Kyung-Jae Lee und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Keimyung University Dongsan Hospital, 1035 Dalgubeol-daero, Dalseo-gu, Daegu 42601, Republic of Korea. Hauptthemen laut MEDLINE: Bone Nails, Hip Fractures, Fracture Fixation, Intramedullary, Fracture Fixation, Internal. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the ministry of SMEs and startup through the technology innovation development program, Ministry of SMEs and Startups.
Abstract (Originalsprache)
Background and Objectives: This biomechanical study aimed to compare the fixation stability of proximal fragments and assess the mechanical properties in models of unstable basicervical intertrochanteric fractures. Materials and Methods: Thirty-six synthetic femur models were utilized. After cephalomedullary nail insertion, unstable basicervical intertrochanteric fractures were created using an engraving machine. Specimens were divided into three groups based on the femoral head fixation method: Group 1 (n = 12, single 100 mm lag screw); Group 2 (n = 12, lag screw + 75 mm anti-rotation screw); and Group 3 (n = 12, lag screw + 95 mm anti-rotation screw). The anti-rotation screws were full-threaded locking screws positioned just below the lag screw. After applying 10,000 vertical cyclic loads, stereophotogrammetry was used to evaluate the proximal fragment rotation in three planes (coronal, sagittal, and axial), and screw-tip displacement was measured radiographically. Vertical load was then applied at a 10 mm/min rate until structural failure.
Results
Rotational change in the sagittal plane was least in Group 3 (Group 1 = 1.7 ± 1.3°, Group 2 = 1.0 ± 0.8°, Group 3 = 0.6 ± 0.6°, p = 0.038). Varus (coronal plane) and retroversion (axial plane) collapse did not differ significantly among the three groups. While cranial migration showed no difference, axial migration was the significantly lowest in Group 3 (Group 1 = 1.07 ± 0.62 mm, Group 2 = 0.60 ± 0.57 mm, Group 3 = 0.50 ± 0.43 mm, p = 0.040). Failure load was slightly higher in Groups 2 and 3 than in Group 1, but without statistical significance. No significant differences were observed between Group 2 and Group 3 in any biomechanical outcomes.
Conclusions
The novel cephalomedullary nail with a long inferior anti-rotation screw significantly reduced rotational instability and axial migration compared to a single-lag screw. There was no significant difference in the rotational stability between the 75 mm and 95 mm anti-rotation screw groups. This novel nail demonstrates superior biomechanical properties in this experimental model and warrants clinical evaluation for treating unstable basicervical intertrochanteric fractures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Keimyung University Dongsan Hospital, 1035 Dalgubeol-daero, Dalseo-gu, Daegu 42601, Republic of Korea.
- Department of Orthopaedic Surgery, Hanyang University Seoul Hospital, 222 Wangsimni-ro, Seongdong-gu, Seoul 04763, Republic of Korea.
- Department of Orthopedic Surgery, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 07345, Republic of Korea.
- Department of Biomedical Engineering, Inje University, Gimhae 50834, Republic of Korea.
- Department of Orthopaedic Surgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang 14068, Republic of Korea.
ORCID-Profile: Kyung-Jae Lee, Incheol Kook, Se-Won Lee, Je-Hyun Yoo
Förderung
- the ministry of SMEs and startup through the technology innovation development program
- Ministry of SMEs and Startups
Zitieren
APA
Lee, K. J., Hwang, K. T., Kook, I., Lee, S. W., Lee, S. J., Yoon, J. H., & Yoo, J. H. (2026). Biomechanical Comparison of Three Different Fixation Methods for Unstable Basicervical Intertrochanteric Fractures Using a Novel Cephalomedullary Nail. Medicina. https://doi.org/10.3390/medicina62020322
Vancouver
Lee KJ, Hwang KT, Kook I, Lee SW, Lee SJ, Yoon JH, et al. Biomechanical Comparison of Three Different Fixation Methods for Unstable Basicervical Intertrochanteric Fractures Using a Novel Cephalomedullary Nail. Medicina. 2026. doi:10.3390/medicina62020322
BibTeX
@article{Lee2026,
author = {Lee, Kyung-Jae and Hwang, Kyu Tae and Kook, Incheol and Lee, Se-Won and Lee, Sung-Jae and Yoon, Jin-Ho and Yoo, Je-Hyun},
title = {Biomechanical Comparison of Three Different Fixation Methods for Unstable Basicervical Intertrochanteric Fractures Using a Novel Cephalomedullary Nail},
journal = {Medicina},
year = {2026},
doi = {10.3390/medicina62020322}
}
EUVIMED