Fachartikel in der Zeitschrift Materials, online erschienen am 11.08.2026. Verfasst von Büşra Karaağaç Eskibağlar und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Dentistry, Faculty of Dentistry, Fırat University, 23119 Elazığ, Turkey. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fırat University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study aimed to compare the marginal gap values of prefabricated zirconia and resin crowns fabricated using different three-dimensional (3D) printing technologies for primary molars using a 3D digital analysis method. Materials and Methods: Forty crowns (n = 10/group) were evaluated, including prefabricated zirconia crowns (NuSmile) and three resin crown systems fabricated using different additive manufacturing technologies: Crowntec (Saremco, DLP), Permanent Crown Resin (Formlabs, SLA), and Graphy TC-80DP (MSLA). All restorations were cemented with self-adhesive resin cement. The specimens were scanned before and after cementation, and the obtained STL datasets were superimposed using the Geomagic Control X software. Marginal gap values were calculated using three-dimensional (3D) digital analysis. Data were analyzed using one-way ANOVA and Games–Howell post hoc tests (α = 0.05).

Results

The mean marginal gap values differed among the groups. The lowest marginal gap value was observed in the Formlabs group (113.22 ± 1.94 µm), followed by that of the Saremco group (118.54 ± 1.58 µm). Higher marginal gap values were recorded in the Graphy group (134.23 ± 2.16 µm), whereas the highest value was observed in the prefabricated zirconia crown group (163.14 ± 3.95 µm). Statistically significant differences were observed among all groups (p < 0.001), with all 3D-printed resin crown systems exhibiting lower marginal gap values than the prefabricated zirconia crowns.

Conclusions

Within the limitations of this in vitro study, 3D-printed resin crowns exhibited superior marginal adaptation compared to prefabricated zirconia crowns. Among the evaluated materials, the SLA-fabricated Formlabs crowns exhibited the lowest marginal gap values. All tested resin crown systems demonstrated marginal gap values within clinically acceptable limits.

Schlagwörter

Stichwörter der Autor:innen

3D printingGeomagic Control Xmarginal gappediatric crownsprefabricated zirconia crowns

Autor:innen und Institutionen

  • Department of Pediatric Dentistry, Faculty of Dentistry, Fırat University, 23119 Elazığ, Turkey.
  • Department of Prosthodontics, Faculty of Dentistry, Fırat University, 23119 Elazığ, Turkey.

ORCID-Profile: Ayşe Rençber Kızılkaya

Förderung

  • Fırat University

Zitieren

APA

Karaağaç Eskibağlar, B., İpek, İ., & Rençber Kızılkaya, A. (2026). Three-Dimensional Evaluation of Marginal Gap in Prefabricated Zirconia and 3D-Printed Pediatric Crowns. Materials, 19(16), 3400. https://doi.org/10.3390/ma19163400

Vancouver

Karaağaç Eskibağlar B, İpek İ, Rençber Kızılkaya A. Three-Dimensional Evaluation of Marginal Gap in Prefabricated Zirconia and 3D-Printed Pediatric Crowns. Materials. 2026;19(16):3400. doi:10.3390/ma19163400

BibTeX
@article{KaraaaEskibalar2026,
  author = {Karaağaç Eskibağlar, Büşra and İpek, İrem and Rençber Kızılkaya, Ayşe},
  title = {Three-Dimensional Evaluation of Marginal Gap in Prefabricated Zirconia and 3D-Printed Pediatric Crowns},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {16},
  pages = {3400},
  doi = {10.3390/ma19163400}
}
Kostenlos starten →