EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Digital Manufacturing and Abutment Design on Full-Arch Implant Prostheses—An In Vitro Study

Shahad Altwaijri, Hanan Alotaibi, Talal M Alnassar iD, Alhanoof Aldegheishem iD

Materials · 29.07.2025 · 18 (15) · 3543

DOI: 10.3390/ma18153543 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 29.07.2025. Verfasst von Shahad Altwaijri und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: This research was funded by the Princess Nourah bint Abdulrahman University Researchers Supporting Project (PNURSP2025R115), Princess Nourah bint Abdulrahman U…, Princess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Achieving accurate fit in implant-supported prostheses is critical for avoiding mechanical complications; however, the influence of digital manufacturing techniques and abutment designs on misfit and preload remains unclear. This study evaluated the impact of different manufacturing techniques (CAD-cast and 3D printing) and abutment connection types (engaging [E], non-engaging [NE]) on the misfit and preload of implant-supported cantilevered fixed dental prostheses (ICFDPs). Misfit was measured at six points using scanning electron microscopy, and preload was assessed via eight strain gauges placed buccally and lingually on four implants. Frameworks were torqued to 35 Ncm, retorqued after 10 min, and subjected to 200,000 cycles of loading. Mean preload values ranged from 173.4 ± 79.5 Ncm (PF) to 330 ± 253.2 Ncm (3DP). Preload trends varied depending on the abutment type and manufacturing technique, with the 3DP group showing higher preload in engaging (E) abutments, whereas the CAD-cast group showed the opposite pattern. Although preload values varied numerically, these differences were not statistically significant (p = 0.5). In terms of misfit, significant differences were observed between groups (p < 0.05), except between CAD-cast E (86.4 ± 17.8 μm) and 3DP E (84.1 ± 19.2 μm). Additionally, E and NE abutments showed significant differences in misfit within both CAD-cast and 3DP groups. Overall, 3DP frameworks showed superior fit over CAD-cast. These findings suggest that 3DP may offer improved clinical outcomes in terms of implant–abutment fit.

Schlagwörter

Stichwörter der Autor:innen

3D printingabutment connection designcantileverdigital manufacturingframeworkfull archimplant-supported FDPmisfit

Autor:innen und Institutionen

  • Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia.
  • Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.

ORCID-Profile: Talal M Alnassar, Alhanoof Aldegheishem

Förderung

  • This research was funded by the Princess Nourah bint Abdulrahman University Researchers Supporting Project (PNURSP2025R115), Princess Nourah bint Abdulrahman U…
  • Princess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia

Zitieren

APA

Altwaijri, S., Alotaibi, H., Alnassar, T. M., & Aldegheishem, A. (2025). Influence of Digital Manufacturing and Abutment Design on Full-Arch Implant Prostheses—An In Vitro Study. Materials, 18(15), 3543. https://doi.org/10.3390/ma18153543

Vancouver

Altwaijri S, Alotaibi H, Alnassar TM, Aldegheishem A. Influence of Digital Manufacturing and Abutment Design on Full-Arch Implant Prostheses—An In Vitro Study. Materials. 2025;18(15):3543. doi:10.3390/ma18153543

BibTeX
@article{Altwaijri2025,
  author = {Altwaijri, Shahad and Alotaibi, Hanan and Alnassar, Talal M and Aldegheishem, Alhanoof},
  title = {Influence of Digital Manufacturing and Abutment Design on Full-Arch Implant Prostheses—An In Vitro Study},
  journal = {Materials},
  year = {2025},
  volume = {18},
  number = {15},
  pages = {3543},
  doi = {10.3390/ma18153543}
}
Kostenlos starten →