EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparison of Milled Full-Arch Implant-Supported Frameworks Realised with a Full Digital Workflow or from Conventional Impression: A Clinical Study

Francesco Pera, Paolo Pesce iD, Francesco Bagnasco, Nicolò Pancini, Massimo Carossa iD, Lorenzo Baldelli, Marco Annunziata iD, Marco Migliorati iD, Domenico Baldi, Maria Menini iD

Materials · 15.01.2023 · 16 (2) · 833

DOI: 10.3390/ma16020833 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 15.01.2023. Verfasst von Francesco Pera und 9 weiteren Autor:innen. Beteiligte Einrichtung: C.I.R. Dental School, Department of Surgical Sciences, University of Turin, 10126 Turin, Italy. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Mech & Human, Mech & Human.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The aim of the present study was to investigate the accuracy of a new digital impression system, comparing it to the plaster impression technique in the realization of full-arch implant-supported metal frameworks.

Methods

We took 11 scans (8 of the upper maxilla and 3 of the lower jaw) on a sample of nine patients previously rehabilitated with fixed full-arch screw-retained prostheses following the Columbus Bridge Protocol (CBP) with four to six implants (total: 51) since at least 4 months. Two impressions were taken for each dental arch: one analogic plaster impression using pick-up copings and an open tray technique and a second one using an intra-oral scanner. Two milled metal substructures were realised. The precision and passivity of the substructures were clinically analysed through the Sheffield test and endo-oral radiographs. Laboratory scans of the plaster casts obtained from an intra-oral scanner (IOS) and of the plaster casts obtained from traditional impression were compared with the intraoral scans following Hausdorff’s method and an industrial digital method of optical detection to measure discrepancies. A Mann–Whitney test was performed in order to investigate average distances between surfaces after the superposition.

Results

The Sheffield test demonstrated an excellent passivity of the frameworks obtained through both the digital and the analogic method. In 81.81% of cases (n = 9) both substructures were found to have a perfect fit with excellent passivity, while in 18.18% (n = 2) of cases the substructures were found to have a very slight discrepancy. From the radiographic examination, no gaps between the frameworks and the implant heads or multiunit abutments were observed, with 100% accuracy. By superimposing digital files of scans according to Hausdorff’s method, a statistically significant discrepancy (p = 0.006) was found between the digital scans and the digital models obtained from plaster impressions. Three-dimensional optical detection found a mean discrepancy of 0.11 mm between the analogic cast and the cast derived from the digital impression.

Conclusions

The present study clinically demonstrates that milled implant-supported full-arch frameworks obtained through a digital scan and the herein described technique have an accuracy comparable to those obtained with traditional plaster impression.

Schlagwörter

Stichwörter der Autor:innen

accuracydental implantsdigital impressionfull-archintraoral scanner

Autor:innen und Institutionen

  • C.I.R. Dental School, Department of Surgical Sciences, University of Turin, 10126 Turin, Italy.
  • Department of Surgical Sciences (DISC), University of Genoa, 16132 Genoa, Italy.
  • Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania "Luigi Vanvitelli", 81100 Caserta, Italy.

ORCID-Profile: Paolo Pesce, Massimo Carossa, Marco Annunziata, Marco Migliorati, Maria Menini

Förderung

  • Mech & Human
  • Mech & Human

Zitieren

APA

Pera, F., Pesce, P., Bagnasco, F., Pancini, N., Carossa, M., Baldelli, L., Annunziata, M., Migliorati, M., Baldi, D., & Menini, M. (2023). Comparison of Milled Full-Arch Implant-Supported Frameworks Realised with a Full Digital Workflow or from Conventional Impression: A Clinical Study. Materials, 16(2), 833. https://doi.org/10.3390/ma16020833

Vancouver

Pera F, Pesce P, Bagnasco F, Pancini N, Carossa M, Baldelli L, et al. Comparison of Milled Full-Arch Implant-Supported Frameworks Realised with a Full Digital Workflow or from Conventional Impression: A Clinical Study. Materials. 2023;16(2):833. doi:10.3390/ma16020833

BibTeX
@article{Pera2023,
  author = {Pera, Francesco and Pesce, Paolo and Bagnasco, Francesco and Pancini, Nicolò and Carossa, Massimo and Baldelli, Lorenzo and Annunziata, Marco and Migliorati, Marco and Baldi, Domenico and Menini, Maria},
  title = {Comparison of Milled Full-Arch Implant-Supported Frameworks Realised with a Full Digital Workflow or from Conventional Impression: A Clinical Study},
  journal = {Materials},
  year = {2023},
  volume = {16},
  number = {2},
  pages = {833},
  doi = {10.3390/ma16020833}
}
Kostenlos starten →