Comparative Evaluation of Conventional and Digital Workflow Impressions for Implant-Supported Restorations
Dentistry Journal · 18.02.2026 · 14 (2) · 120
DOI: 10.3390/dj14020120 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentistry Journal, online erschienen am 18.02.2026. Verfasst von Cristian Abad-Coronel und 5 weiteren Autor:innen. Beteiligte Einrichtung: Research Group in Digital Dentistry and CAD/CAM Materials, Faculty of Dentistry, Universidad de Cuenca, Cuenca 010107, Ecuador. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Digital technologies, particularly CAD/CAM workflows, have transformed implant prosthodontics by improving the accuracy and efficiency of impression procedures, facilitating clinician–laboratory communication, and supporting the preservation of peri-implant tissues.
Objective
To compare the three-dimensional accuracy (trueness) and passive fit of five conventional and digital impression techniques for fixed prostheses supported by two implants.
Methods
An in vitro experimental study was conducted using a partially edentulous maxillary model with two implants supporting a three-unit zirconia bridge. Five impression workflows were evaluated: conventional techniques (open-tray and closed-tray, splinted and non-splinted) and digital impressions using plastic and titanium scan bodies. Three-dimensional accuracy was assessed by digital superimposition analysis, and passive fit was evaluated by marginal gap measurements using digital microscopy and ImageJ (version 1.54r) software. Statistical analyses were performed using exploratory ANOVA with Welch’s correction and Games–Howell post hoc tests (p < 0.05), complemented by effect size analysis.
Results
Three-dimensional superimposition analysis revealed that digital impression workflows and the splinted conventional open-tray technique exhibited the highest trueness, with minimal spatial deviations relative to the reference model, together with the lowest marginal gap values (
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Research Group in Digital Dentistry and CAD/CAM Materials, Faculty of Dentistry, Universidad de Cuenca, Cuenca 010107, Ecuador.
- Prostodonthics Departament, Faculty of Dentistry, Universidad San Francisco de Quito, Quito 170901, Ecuador.
ORCID-Profile: Cristian Abad-Coronel
Zitieren
APA
Abad-Coronel, C., Ruiz, D., Quelal, M. Á., Estrada, D., Mena Córdova, N., & Aliaga, P. (2026). Comparative Evaluation of Conventional and Digital Workflow Impressions for Implant-Supported Restorations. Dentistry Journal, 14(2), 120. https://doi.org/10.3390/dj14020120
Vancouver
Abad-Coronel C, Ruiz D, Quelal MÁ, Estrada D, Mena Córdova N, Aliaga P. Comparative Evaluation of Conventional and Digital Workflow Impressions for Implant-Supported Restorations. Dentistry Journal. 2026;14(2):120. doi:10.3390/dj14020120
BibTeX
@article{AbadCoronel2026,
author = {Abad-Coronel, Cristian and Ruiz, David and Quelal, Miguel Ángel and Estrada, Diana and Mena Córdova, Nancy and Aliaga, Paulina},
title = {Comparative Evaluation of Conventional and Digital Workflow Impressions for Implant-Supported Restorations},
journal = {Dentistry Journal},
year = {2026},
volume = {14},
number = {2},
pages = {120},
doi = {10.3390/dj14020120}
}
EUVIMED