Preliminary Evaluation of Cell Population Data Parameters in Different Blood Collection Tubes on Sysmex XN-Series Analysers

James V. Harte, Ciara Hoy, Vitaliy Mykytiv

LabMed · 2025

DOI: 10.3390/labmed2030015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift LabMed, 2025. Verfasst von James V. Harte und 2 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cell population data (CPD) parameters generated by Sysmex XN-series analysers are promising biomarkers for a variety of disease states. Routine use of CPD parameters, however, will require extensive evaluation of potential pre-analytical variables that may affect reliability. At present, no information on the comparability of CPD parameters generated using different blood collection tubes is available. In this preliminary study, we evaluated the impact of four commonly used blood collection tubes—dipotassium (K2) EDTA, tripotassium (K3) EDTA, trisodium citrate, and lithium heparin—on the generation of CPD parameters in whole blood from a cohort of 10 healthy donors. We also evaluated the stability of the CPD parameters generated at 4 h post-collection. Statistically significant differences in the CPD were observed across all blood collection tubes: whole blood anticoagulated with K3EDTA induced minimal biases and was comparable to whole blood anticoagulated with K2EDTA at collection; however, whole blood anticoagulated with citrate and heparin were associated with more substantial and more widespread biases in several parameters with potential clinical relevance. Notably, the biases observed in whole blood anticoagulated with K3EDTA increased in both number and magnitude at 4 h post-collection, whilst the CPD parameters generated with whole blood anticoagulated with K2EDTA remained stable. Although further confirmatory investigations are required, these findings highlight the importance of anticoagulant selection, as well as the need for further pre-analytical research, to support the integration of CPD parameters generated by Sysmex XN-series analysers into routine diagnostic workflows.

Zitieren

APA

Harte, J. V., Hoy, C., & Mykytiv, V. (2025). Preliminary Evaluation of Cell Population Data Parameters in Different Blood Collection Tubes on Sysmex XN-Series Analysers. LabMed. https://doi.org/10.3390/labmed2030015

Vancouver

Harte JV, Hoy C, Mykytiv V. Preliminary Evaluation of Cell Population Data Parameters in Different Blood Collection Tubes on Sysmex XN-Series Analysers. LabMed. 2025. doi:10.3390/labmed2030015

BibTeX
@article{Harte2025,
  author = {Harte, James V. and Hoy, Ciara and Mykytiv, Vitaliy},
  title = {Preliminary Evaluation of Cell Population Data Parameters in Different Blood Collection Tubes on Sysmex XN-Series Analysers},
  journal = {LabMed},
  year = {2025},
  doi = {10.3390/labmed2030015}
}
Kostenlos starten →