EUVIMEDEUVIMED entdecken
Crossref

The Leucocyte Cell Population Data as Measured by the Sysmex XN ‐Series Hematology Analyzer Changes More Rapidly Over Time Than Other Biomarkers During the Treatment of Bacteremia

Sadashi Horie iD, Mizuki Yamashita, Kenta Matsumura, Yoji Uejima, Makito Kaneda, Kentaro Nagaoka, Kentaro Tamura iD, Kenu Harada, Canh Thang Tran, Yoshihiro Yamamoto, Isao Kitajima, Chihaya Imai iD und 1 weitere

International Journal of Laboratory Hematology · 2026-12 · 48 (6) · 1348-1355

DOI: 10.1111/ijlh.70201 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Laboratory Hematology, online erschienen am 21.07.2026. Verfasst von Sadashi Horie und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatrics, Faculty of Medicine, University of Toyama, Toyama, Japan. Hauptthemen laut MEDLINE: Bacteremia, Leukocytes. Die Arbeit nennt 28 Literaturangaben. Gefördert von: Charitable Trust Pediatrics Research Promotion Fund, JSPS KAKENHI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Cell population data (CPD) from the Sysmex XN‐Series hematology analyzer have attracted attention as a new leukocyte biomarker in the field of infectious diseases. For CPD, we focused on the fluorescent light distribution of the neutrophil area (NE‐WY) and recently reported that it is useful for the early diagnosis of bacteremia. In clinical practice, the rapid assessment of the effectiveness of antibiotic treatment is as important as the early recognition of bacteremia, but it is still unclear whether NE‐WY is useful.

Methods

We compared the time‐dependent changes in NE‐WY with parameters commonly used in 54 patients with bacteremia who responded well to initial antibiotic treatment.

Results

NE ‐ WY peaked approximately 1 day earlier than C‐reactive protein ( CRP ) and returned to baseline levels significantly earlier. Additionally, NE ‐ WY fluctuated in a similar manner as white blood cells ( WBCs ) and neutrophils (Neut), but NE ‐ WY had narrower error bars and tended to reach a plateau at the reference value more quickly.

Conclusion

This is the first report to demonstrate that NE‐WY is a highly useful biomarker not only for diagnosing bacteremia but also for assessing the therapeutic efficacy of antibiotics. NE‐WY changes more rapidly over time than other biomarkers during the treatment of bacteremia. Thus, NE‐WY has the potential to become a key biomarker in the field of infectious diseases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BacteremiaLeukocytesHumansBiomarkersAnti-Bacterial AgentsFemaleLeukocyte CountMaleNeutrophilsMiddle AgedAgedAdultTime Factors

Stichwörter der Autor:innen

NE‐WYbacteremiacell population dataleukocyte biomarkertime‐dependent change

Substanzen

BiomarkersAnti-Bacterial Agents

Autor:innen und Institutionen

  • Department of Pediatrics, Faculty of Medicine, University of Toyama, Toyama, Japan.
  • Department of Clinical Laboratory and Transfusion Medicine & Cell Therapy Center, Toyama University Hospital, Toyama, Japan.
  • Graduate School of Health Sciences, Aomori University of Health and Welfare, Aomori, Japan.
  • Department of Infectious Diseases, Immunology and Allergy, Saitama Prefectural Children's Medical Center, Saitama, Japan.
  • Department of Clinical Infectious Diseases, Faculty of Medicine, University of Toyama, Toyama, Japan.
  • Administrative Office, University of Toyama, Toyama, Japan.

ORCID-Profile: Sadashi Horie, Kentaro Tamura, Chihaya Imai

Förderung

  • Charitable Trust Pediatrics Research Promotion Fund
  • JSPS KAKENHI

Zitieren

APA

Horie, S., Yamashita, M., Matsumura, K., Uejima, Y., Kaneda, M., Nagaoka, K., Tamura, K., Harada, K., Tran, C. T., Yamamoto, Y., Kitajima, I., Imai, C., & Niimi, H. (2026). The Leucocyte Cell Population Data as Measured by the Sysmex XN ‐Series Hematology Analyzer Changes More Rapidly Over Time Than Other Biomarkers During the Treatment of Bacteremia. International Journal of Laboratory Hematology, 48(6), 1348-1355. https://doi.org/10.1111/ijlh.70201

Vancouver

Horie S, Yamashita M, Matsumura K, Uejima Y, Kaneda M, Nagaoka K, et al. The Leucocyte Cell Population Data as Measured by the Sysmex XN ‐Series Hematology Analyzer Changes More Rapidly Over Time Than Other Biomarkers During the Treatment of Bacteremia. International Journal of Laboratory Hematology. 2026;48(6):1348-1355. doi:10.1111/ijlh.70201

BibTeX
@article{Horie2026,
  author = {Horie, Sadashi and Yamashita, Mizuki and Matsumura, Kenta and Uejima, Yoji and Kaneda, Makito and Nagaoka, Kentaro and Tamura, Kentaro and Harada, Kenu and Tran, Canh Thang and Yamamoto, Yoshihiro and Kitajima, Isao and Imai, Chihaya and Niimi, Hideki},
  title = {The Leucocyte Cell Population Data as Measured by the Sysmex XN ‐Series Hematology Analyzer Changes More Rapidly Over Time Than Other Biomarkers During the Treatment of Bacteremia},
  journal = {International Journal of Laboratory Hematology},
  year = {2026},
  volume = {48},
  number = {6},
  pages = {1348--1355},
  doi = {10.1111/ijlh.70201}
}