Dental Root Injuries Caused by Osteosynthesis Screws in Orthognathic Surgery—Comparison of Conventional Osteosynthesis and Osteosynthesis by CAD/CAM Drill Guides and Patient-Specific Implants
Journal of Personalized Medicine · 23.04.2023 · 13 (5) · 706
DOI: 10.3390/jpm13050706 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Personalized Medicine, online erschienen am 23.04.2023. Verfasst von Sebastian Pietzka und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cranio-Maxillo-Facial-Surgery, University Hospital Ulm, 89081 Ulm, Germany. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/Aim: The primary aim was to evaluate the prevalence and localisation of dental injuries caused by osteosynthesis screws during orthognathic surgery, comparing two different CAD/CAM planning/surgical approaches through retrospective evaluation of post-operative computed tomography. Material and Methods: This study considered all patients who underwent orthognathic surgery from 2010–2019. The examination for dental root injuries between conventional osteosynthesis (Maxilla conventional cohort) and osteosynthesis with patient-specific implant (Maxilla PSI cohort) was performed by evaluating the post-operative CT scans.
Results
A total of 126 patients were included in the study. Among the 61 patients of the Maxilla conventional cohort, 10 dental root injuries in 8 patients (13.1%) were detected in the post-operative CT scan, representing 1.5% (n = 10/651) of the osteosynthesis screws inserted in proximity of the alveolar crest. No dental injury occurred following osteosynthesis in the 65 patients of the Maxillary PSI cohort (n = 0/773 screws) (p < 0.001). During a mean follow-up period of 13 months after primary surgery, none of the injured teeth showed evidence of periapical alterations and no endodontic treatments were necessary.
Conclusions
Maxillary positioning using CAD/CAM-fabricated drill/osteotomy guide and osteosynthesis with PSI can significantly reduce the risk for dental injury compared to the conventional procedure. However, the clinical significance of the detected dental injuries was rather minor.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cranio-Maxillo-Facial-Surgery, University Hospital Ulm, 89081 Ulm, Germany.
- Department of Cranio-Maxillo-Facial-Surgery, German Armed Forces Hospital, 89081 Ulm, Germany.
- Institute of Anatomy, Medical Faculty, University of Leipzig, 04109 Leipzig, Germany.
ORCID-Profile: Sebastian Pietzka
Zitieren
APA
Pietzka, S., Fink, J., Winter, K., Wilde, F., Schramm, A., Ebeling, M., Kasper, R., & Sakkas, A. (2023). Dental Root Injuries Caused by Osteosynthesis Screws in Orthognathic Surgery—Comparison of Conventional Osteosynthesis and Osteosynthesis by CAD/CAM Drill Guides and Patient-Specific Implants. Journal of Personalized Medicine, 13(5), 706. https://doi.org/10.3390/jpm13050706
Vancouver
Pietzka S, Fink J, Winter K, Wilde F, Schramm A, Ebeling M, et al. Dental Root Injuries Caused by Osteosynthesis Screws in Orthognathic Surgery—Comparison of Conventional Osteosynthesis and Osteosynthesis by CAD/CAM Drill Guides and Patient-Specific Implants. Journal of Personalized Medicine. 2023;13(5):706. doi:10.3390/jpm13050706
BibTeX
@article{Pietzka2023,
author = {Pietzka, Sebastian and Fink, Juliana and Winter, Karsten and Wilde, Frank and Schramm, Alexander and Ebeling, Marcel and Kasper, Robin and Sakkas, Andreas},
title = {Dental Root Injuries Caused by Osteosynthesis Screws in Orthognathic Surgery—Comparison of Conventional Osteosynthesis and Osteosynthesis by CAD/CAM Drill Guides and Patient-Specific Implants},
journal = {Journal of Personalized Medicine},
year = {2023},
volume = {13},
number = {5},
pages = {706},
doi = {10.3390/jpm13050706}
}
EUVIMED