EUVIMEDEUVIMED entdecken
Klinische StudieVergleichsstudieOpen Access · CC BY-NC-ND 4.0

Prospective Clinical Study on the Accuracy of Static Computer‐Assisted Implant Surgery in Patients With Distal Free‐End Implants. Conventional Versus CAD ‐ CAM Surgical Guides

García-Mira Berta iD, Canullo Luigi, Peñarrocha-Diago Miguel, Balaguer-Martí José Carlos

Clinical Oral Implants Research · 2025-03 · 36 (3) · 314-324

DOI: 10.1111/clr.14384 ↗

Kurz gefasst

Klinische Studie in der Zeitschrift Clinical Oral Implants Research, online erschienen am 23.11.2024. Verfasst von García-Mira Berta und 3 weiteren Autor:innen. Beteiligte Einrichtung: University of Valencia, Valencia, Spain. Hauptthemen laut MEDLINE: Computer-Aided Design, Dental Implantation, Endosseous, Dental Implants, Surgery, Computer-Assisted. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To compare the accuracy of CAD‐CAM and conventional guides in the static computer‐assisted implant surgery (sCAIS) placement of distal free‐end implants. Material and Methods A prospective, controlled, and blinded quasi‐experimental study was done involving 27 patients (76 implants) distributed into two groups according to the surgical guide manufacturing approach used: conventional (control group [CG]) or CAD‐CAM (test group [TG]). The implants were planned in the software and the surgical guides were manufactured. Fully guided implant placement was carried out and the deviations were measured along with secondary variables as potential confounding factors. Descriptive analyses were performed on mean, standard deviation (SD), and interquartile range (IQR). In the comparative/inferential analysis hypothesis, contrasts were made of the quantitative and qualitative variables and multiple linear models were generated to adjust for the different confounding variables recorded.

Results

Coronal horizontal deviation (CHD) was significantly greater in CG (1.52 mm) versus TG (1.04 mm) ( p = 0.004). Apical horizontal deviation (AHD) in turn was 1.67 versus 1.46 mm, respectively; angular deviation was 2.87 versus 3.64; and vertical deviation was −0.1 versus −0.05 mm, with no significant differences between the groups ( p > 0.05). A greater sleeve height, positioning in premolars versus molars, and the use of shorter implants, were associated with greater accuracy in relation to CHD and/or AHD ( p < 0.05). The implant success rate at 1 year was 92.1%, 90.7% in TG, and 100% in CG, being statistically significant ( p = 0.026) at the implant level, but not significant at the patient level.

Conclusions

The CAD‐CAM surgical guides proved to be more accurate than the conventional guides in the sCAIS placement of distal free‐end implants, with statistically significant differences being observed in terms of CHD. All implant failures occurred in TG (6 implants/3 patients). Trial Registration ClinicalTrials.gov identifier: NCT06404385

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computer-Aided DesignDental Implantation, EndosseousDental ImplantsSurgery, Computer-AssistedAdultAgedFemaleHumansMaleMiddle AgedProspective Studies

Stichwörter der Autor:innen

accuracyanalogiccomputer‐aided designcomputer‐assisted surgerydental implants

Substanzen

Dental Implants

Autor:innen und Institutionen

  • University of Valencia, Valencia, Spain.
  • Department of Surgical Sciences, University of Genova, Genova, Italy.

ORCID-Profile: García-Mira Berta

Zitieren

APA

Berta, G. M., Luigi, C., Miguel, P. D., & Carlos, B. J. (2025). Prospective Clinical Study on the Accuracy of Static Computer‐Assisted Implant Surgery in Patients With Distal Free‐End Implants. Conventional Versus CAD ‐ CAM Surgical Guides. Clinical Oral Implants Research, 36(3), 314-324. https://doi.org/10.1111/clr.14384

Vancouver

Berta GM, Luigi C, Miguel PD, Carlos BJ. Prospective Clinical Study on the Accuracy of Static Computer‐Assisted Implant Surgery in Patients With Distal Free‐End Implants. Conventional Versus CAD ‐ CAM Surgical Guides. Clinical Oral Implants Research. 2025;36(3):314-324. doi:10.1111/clr.14384

BibTeX
@article{Berta2025,
  author = {Berta, García-Mira and Luigi, Canullo and Miguel, Peñarrocha-Diago and Carlos, Balaguer-Martí José},
  title = {Prospective Clinical Study on the Accuracy of Static Computer‐Assisted Implant Surgery in Patients With Distal Free‐End Implants. Conventional Versus CAD ‐ CAM Surgical Guides},
  journal = {Clinical Oral Implants Research},
  year = {2025},
  volume = {36},
  number = {3},
  pages = {314--324},
  doi = {10.1111/clr.14384}
}
Kostenlos starten →