EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitSystematische ÜbersichtMetaanalyseOpen Access · CC BY 4.0

Adjunct Automated Breast Ultrasound in Mammographic Screening: A Systematic Review and Meta-Analysis

Ghufran Jassim iD, Fahad AlZayani, Suchita Dsilva iD

Journal of Imaging · 22.12.2025 · 12 (1) · 3

DOI: 10.3390/jimaging12010003 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Imaging, online erschienen am 22.12.2025. Verfasst von Ghufran Jassim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Family Medicine, School of Medicine, Royal College of Surgeons in Ireland-Medical University of Bahrain, Busaiteen 15503, Bahrain. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Mammographic sensitivity is reduced in women with dense breasts, leading to missed cancers and a higher burden of interval cancers. Automated breast ultrasound (ABUS) and ultrasound tomography (UST) have been introduced as supplemental breast imaging modalities, but primary studies are heterogeneous, and previous reviews have not focused on screening settings or on head-to-head comparisons with handheld ultrasound (HHUS). We systematically searched PubMed, Embase, Web of Science and the Cochrane Library for studies from 1 January 2000 to 31 May 2025 evaluating ABUS or UST as adjuncts to mammographic screening. Two reviewers independently selected studies and assessed risk of bias. When at least two clinically comparable studies were available, we pooled sensitivity and specificity using random-effects bivariate meta-analysis. Eighteen studies (just over 20,000 screening or recall episodes) met the inclusion criteria; 16 evaluated ABUS/ABVS and 2 UST. Adding ABUS to mammography increased sensitivity by 6–35 percentage points and improved cancer detection by 2.4–4.3 per 1000 women with dense breasts, with higher recall rates and modest reductions in specificity. When ABUS was compared directly with HHUS, pooled sensitivity was 0.90 and specificity 0.89, with HHUS showing slightly lower sensitivity and slightly higher specificity. Only two studies had an overall low risk of bias, and heterogeneity (particularly for specificity) was substantial. ABUS is a practical and scalable adjunct to mammography that increases cancer detection in women with dense breasts, with an expected trade-off of higher recall and modest specificity loss. Its comparative diagnostic accuracy appears broadly non-inferior to HHUS. However, the predominance of high-risk-of-bias studies and between-study heterogeneity means that high-quality population-based trials and standardised reporting are still required before widespread implementation in organised screening programmes.

Schlagwörter

Stichwörter der Autor:innen

automated breast ultrasoundbreast densitydiagnostic accuracyhandheld ultrasoundmammographyscreening

Autor:innen und Institutionen

  • Department of Family Medicine, School of Medicine, Royal College of Surgeons in Ireland-Medical University of Bahrain, Busaiteen 15503, Bahrain.
  • School of Medicine, Arabian Gulf University, Manama 22979, Bahrain.

ORCID-Profile: Ghufran Jassim, Suchita Dsilva

Zitieren

APA

Jassim, G., AlZayani, F., & Dsilva, S. (2025). Adjunct Automated Breast Ultrasound in Mammographic Screening: A Systematic Review and Meta-Analysis. Journal of Imaging, 12(1), 3. https://doi.org/10.3390/jimaging12010003

Vancouver

Jassim G, AlZayani F, Dsilva S. Adjunct Automated Breast Ultrasound in Mammographic Screening: A Systematic Review and Meta-Analysis. Journal of Imaging. 2025;12(1):3. doi:10.3390/jimaging12010003

BibTeX
@article{Jassim2025,
  author = {Jassim, Ghufran and AlZayani, Fahad and Dsilva, Suchita},
  title = {Adjunct Automated Breast Ultrasound in Mammographic Screening: A Systematic Review and Meta-Analysis},
  journal = {Journal of Imaging},
  year = {2025},
  volume = {12},
  number = {1},
  pages = {3},
  doi = {10.3390/jimaging12010003}
}
Kostenlos starten →